WEKO3
アイテム
{"_buckets": {"deposit": "1ff863f2-e30f-471c-b8d6-2aea61c35f3d"}, "_deposit": {"created_by": 1, "id": "54904", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54904"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054904", "sets": ["2"]}, "author_link": ["561446", "561454", "561448", "561452", "561443", "561445", "561444", "561451", "561453", "561450", "561447", "561449"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-11", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "338", "bibliographicPageStart": "333", "bibliographic_titles": [{"bibliographic_title": "Proceeding of the 18th Workshop on Environmental Radioactivity 2017"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "RAD7を用いたバブリング法は,水中ラドン濃度25 kBq m−3以上で,鉱泉分析法指針に記載されている液体シンチレーションカウンタによる定量と同等に測定できることが分かった。空気中ラドン濃度においては,測定器としての感度がRAD7の10倍程度高い基準モニタとRAD7での並行測定を行い,RAD7が基準モニタと同等に測定できるには,252カウント必要であることが分かった。このことから,バブリング法で,RAD7の250 mL容器を用いて20分測定 (5分4回) した場合,水中ラドン濃度5 kBq m−3が測定下限値であることがわかった。この下限値が10 kBq m−3以下のため,飲料水ラドン濃度基準値100 kBq m−3の判断に,バブリング法を用いることができることがわかった。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "神代悠希"}], "nameIdentifiers": [{"nameIdentifier": "561443", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石原万己"}], "nameIdentifiers": [{"nameIdentifier": "561444", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤井さとみ"}], "nameIdentifiers": [{"nameIdentifier": "561445", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安岡由美"}], "nameIdentifiers": [{"nameIdentifier": "561446", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "細田正洋"}], "nameIdentifiers": [{"nameIdentifier": "561447", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岩岡和輝"}], "nameIdentifiers": [{"nameIdentifier": "561448", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "床次眞司"}], "nameIdentifiers": [{"nameIdentifier": "561449", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ミロソラフ, ヤニック"}], "nameIdentifiers": [{"nameIdentifier": "561450", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "武藤潤"}], "nameIdentifiers": [{"nameIdentifier": "561451", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長濱裕幸"}], "nameIdentifiers": [{"nameIdentifier": "561452", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "向高弘"}], "nameIdentifiers": [{"nameIdentifier": "561453", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "ミロソラフ ヤニック", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "561454", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "バブリング法による水中ラドン濃度測定について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "バブリング法による水中ラドン濃度測定について"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54904", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-05-15"}, "publish_date": "2018-05-15", "publish_status": "0", "recid": "54904", "relation": {}, "relation_version_is_last": true, "title": ["バブリング法による水中ラドン濃度測定について"], "weko_shared_id": -1}
バブリング法による水中ラドン濃度測定について
https://repo.qst.go.jp/records/54904
https://repo.qst.go.jp/records/54904d75834af-43d5-44bd-aa34-091b7f6c9e70
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-05-15 | |||||
タイトル | ||||||
タイトル | バブリング法による水中ラドン濃度測定について | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
神代悠希
× 神代悠希× 石原万己× 藤井さとみ× 安岡由美× 細田正洋× 岩岡和輝× 床次眞司× ミロソラフ, ヤニック× 武藤潤× 長濱裕幸× 向高弘× ミロソラフ ヤニック |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | RAD7を用いたバブリング法は,水中ラドン濃度25 kBq m−3以上で,鉱泉分析法指針に記載されている液体シンチレーションカウンタによる定量と同等に測定できることが分かった。空気中ラドン濃度においては,測定器としての感度がRAD7の10倍程度高い基準モニタとRAD7での並行測定を行い,RAD7が基準モニタと同等に測定できるには,252カウント必要であることが分かった。このことから,バブリング法で,RAD7の250 mL容器を用いて20分測定 (5分4回) した場合,水中ラドン濃度5 kBq m−3が測定下限値であることがわかった。この下限値が10 kBq m−3以下のため,飲料水ラドン濃度基準値100 kBq m−3の判断に,バブリング法を用いることができることがわかった。 | |||||
書誌情報 |
Proceeding of the 18th Workshop on Environmental Radioactivity 2017 p. 333-338, 発行日 2017-11 |