WEKO3
アイテム
{"_buckets": {"deposit": "379729bc-349b-4e79-962d-b97510f6b4ca"}, "_deposit": {"created_by": 1, "id": "46976", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "46976"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00046976", "sets": ["1"]}, "author_link": ["468863", "468868", "468865", "468867", "468864", "468870", "468866", "468869", "468862", "468871"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "23", "bibliographicPageEnd": "3398", "bibliographicPageStart": "3392", "bibliographicVolumeNumber": "32", "bibliographic_titles": [{"bibliographic_title": "Electrophoresis"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Fraction collection of selected components from a complex mixture plays a critical role in biomedical research, environmental analysis, and biotechnology. Here, we introduce a novel electrophoretic chip device based on a signal processing theorem that allows simultaneous space sampling for fractionation of ssDNA target fragments. Ten parallel extraction channels, which covered 1.5-mm-long sampling ranges, were used to facilitate the capturing of fast-moving fragments. Furthermore, the space sampling extraction made it possible to acquire pure collection, even from partly overlapping fragments that had been insufficiently separated after a short electrophoretic run. Fragments of 180, 181, and 182 bases were simultaneously collected, and then the recovered DNA was PCR amplified and assessed by CE analysis. The 181-base target was shown to be isolated in a 70-mm-long separation length within 10 min, in contrast to the \u003e50 min required for the 300-mm-long separation channel in our previous study. This method provides effective combination of time and space, which is a breakthrough in the traditional concept of fraction collection on a chip.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Wiley-VCH"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "22072547", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1002/elps.201100362", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0173-0835", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Li, Zheyu"}], "nameIdentifiers": [{"nameIdentifier": "468862", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sun, Kai"}], "nameIdentifiers": [{"nameIdentifier": "468863", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sunayama, Misato"}], "nameIdentifiers": [{"nameIdentifier": "468864", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Araki, Ryoko"}], "nameIdentifiers": [{"nameIdentifier": "468865", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ueno, Kosei"}], "nameIdentifiers": [{"nameIdentifier": "468866", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Abe, Masumi"}], "nameIdentifiers": [{"nameIdentifier": "468867", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Misawa, Hiroaki"}], "nameIdentifiers": [{"nameIdentifier": "468868", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "砂山 美里", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "468869", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "荒木 良子", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "468870", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "安倍 真澄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "468871", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A simultaneous space sampling method for DNA fraction collection using a comb structure in microfluidic devices.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "A simultaneous space sampling method for DNA fraction collection using a comb structure in microfluidic devices."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/46976", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-12-01"}, "publish_date": "2014-12-01", "publish_status": "0", "recid": "46976", "relation": {}, "relation_version_is_last": true, "title": ["A simultaneous space sampling method for DNA fraction collection using a comb structure in microfluidic devices."], "weko_shared_id": -1}
A simultaneous space sampling method for DNA fraction collection using a comb structure in microfluidic devices.
https://repo.qst.go.jp/records/46976
https://repo.qst.go.jp/records/46976722cf05e-80e2-46f0-bf64-049b1a12e5b5
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-12-01 | |||||
タイトル | ||||||
タイトル | A simultaneous space sampling method for DNA fraction collection using a comb structure in microfluidic devices. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Li, Zheyu
× Li, Zheyu× Sun, Kai× Sunayama, Misato× Araki, Ryoko× Ueno, Kosei× Abe, Masumi× Misawa, Hiroaki× 砂山 美里× 荒木 良子× 安倍 真澄 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Fraction collection of selected components from a complex mixture plays a critical role in biomedical research, environmental analysis, and biotechnology. Here, we introduce a novel electrophoretic chip device based on a signal processing theorem that allows simultaneous space sampling for fractionation of ssDNA target fragments. Ten parallel extraction channels, which covered 1.5-mm-long sampling ranges, were used to facilitate the capturing of fast-moving fragments. Furthermore, the space sampling extraction made it possible to acquire pure collection, even from partly overlapping fragments that had been insufficiently separated after a short electrophoretic run. Fragments of 180, 181, and 182 bases were simultaneously collected, and then the recovered DNA was PCR amplified and assessed by CE analysis. The 181-base target was shown to be isolated in a 70-mm-long separation length within 10 min, in contrast to the >50 min required for the 300-mm-long separation channel in our previous study. This method provides effective combination of time and space, which is a breakthrough in the traditional concept of fraction collection on a chip. | |||||
書誌情報 |
Electrophoresis 巻 32, 号 23, p. 3392-3398, 発行日 2011-11 |
|||||
出版者 | ||||||
出版者 | Wiley-VCH | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0173-0835 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 22072547 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/elps.201100362 |