ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Conversion coefficients from ambient dose equivalent to effective doses of various age groups in areas affected by the 2011 Fukushima nuclear disaster

https://repo.qst.go.jp/records/86586
https://repo.qst.go.jp/records/86586
9c7307a4-83a2-4122-b35b-eee2e47eb09c
Item type 会議発表用資料 / Presentation(1)
公開日 2022-07-08
タイトル
タイトル Conversion coefficients from ambient dose equivalent to effective doses of various age groups in areas affected by the 2011 Fukushima nuclear disaster
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Masayuki, Naito

× Masayuki, Naito

WEKO 1058314

Masayuki, Naito

Search repository
Yuki, Tamakuma

× Yuki, Tamakuma

WEKO 1058315

Yuki, Tamakuma

Search repository
Kazuaki, Yajima

× Kazuaki, Yajima

WEKO 1058316

Kazuaki, Yajima

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 1058317

Eunjoo, Kim

Search repository
Satoshi, Obara

× Satoshi, Obara

WEKO 1058318

Satoshi, Obara

Search repository
Osamu, Kurihara

× Osamu, Kurihara

WEKO 1058319

Osamu, Kurihara

Search repository
Masayuki, Naito

× Masayuki, Naito

WEKO 1058320

en Masayuki, Naito

Search repository
Yuki, Tamakuma

× Yuki, Tamakuma

WEKO 1058321

en Yuki, Tamakuma

Search repository
Kazuaki, Yajima

× Kazuaki, Yajima

WEKO 1058322

en Kazuaki, Yajima

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 1058323

en Eunjoo, Kim

Search repository
Satoshi, Obara

× Satoshi, Obara

WEKO 1058324

en Satoshi, Obara

Search repository
Osamu, Kurihara

× Osamu, Kurihara

WEKO 1058325

en Osamu, Kurihara

Search repository
抄録
内容記述タイプ Abstract
内容記述 In case of nuclear accidents, it is important to determine the magnitude of radiation doses received by people living in contaminated territories. Direct measurement of individual external doses using personal dosimeters (PDs) worn by subjects is the most reliable solution for this necessity. However, it is not practical to expect that all returnees to the affected areas wear PDs. Thus, conversion factors from the ambient dose equivalent (ADEs) to the effective dose for various aged individuals must be determined appropriately. Previous studies demonstrated that the ratio of PDs to ADEs at various areas of Fukushima Prefecture mostly existed in the range of 0.6-0.7 [e.g.,1-3]. These studies provided evidence that PD readings would be reasonable estimators for the effective doses of adult subjects at locations where radioactive cesium is widely and uniformly deposited on the ground. In the present study, we experimentally obtained the response of PDs (D-shuttle, Chiyoda Technol., Tokyo, Japan; Dose i, Fuji Electric, Tokyo, Japan) attached to the front of five age-specific anthropometric phantoms (newborn, 1 y, 5y, 10y and adult male) for lateral radiations of 137Cs with various rotational angles. The PD/ADE ratio for the D-shuttle on the five phantoms with rotational irradiation simulating the exposure in Fukushima Prefecture were 0.87, 0.85, 0.83, 0.83 and 0.77, respectively. The ratio for newborns was 11 % higher than that for adult males. This body size dependency can be explained by the PD response to exposure direction. We discussed the results of this study and our field experiments to construct conversion coefficients from the ADE to the effective doses for age-group residents living in affected areas, which will be presented at the conference.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Conference on Individual Monitoring of Ionising Radiation (IM2022) and Neutron and Ion Dosimetry Symposium (NEUDOS-14)
発表年月日
日付 2022-04-28
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:45:39.423757
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3