WEKO3
アイテム
Conversion coefficients from ambient dose equivalent to effective doses of various age groups in areas affected by the 2011 Fukushima nuclear disaster
https://repo.qst.go.jp/records/86586
https://repo.qst.go.jp/records/865869c7307a4-83a2-4122-b35b-eee2e47eb09c
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-07-08 | |||||
タイトル | ||||||
タイトル | Conversion coefficients from ambient dose equivalent to effective doses of various age groups in areas affected by the 2011 Fukushima nuclear disaster | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Masayuki, Naito
× Masayuki, Naito× Yuki, Tamakuma× Kazuaki, Yajima× Eunjoo, Kim× Satoshi, Obara× Osamu, Kurihara× Masayuki, Naito× Yuki, Tamakuma× Kazuaki, Yajima× Eunjoo, Kim× Satoshi, Obara× Osamu, Kurihara |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In case of nuclear accidents, it is important to determine the magnitude of radiation doses received by people living in contaminated territories. Direct measurement of individual external doses using personal dosimeters (PDs) worn by subjects is the most reliable solution for this necessity. However, it is not practical to expect that all returnees to the affected areas wear PDs. Thus, conversion factors from the ambient dose equivalent (ADEs) to the effective dose for various aged individuals must be determined appropriately. Previous studies demonstrated that the ratio of PDs to ADEs at various areas of Fukushima Prefecture mostly existed in the range of 0.6-0.7 [e.g.,1-3]. These studies provided evidence that PD readings would be reasonable estimators for the effective doses of adult subjects at locations where radioactive cesium is widely and uniformly deposited on the ground. In the present study, we experimentally obtained the response of PDs (D-shuttle, Chiyoda Technol., Tokyo, Japan; Dose i, Fuji Electric, Tokyo, Japan) attached to the front of five age-specific anthropometric phantoms (newborn, 1 y, 5y, 10y and adult male) for lateral radiations of 137Cs with various rotational angles. The PD/ADE ratio for the D-shuttle on the five phantoms with rotational irradiation simulating the exposure in Fukushima Prefecture were 0.87, 0.85, 0.83, 0.83 and 0.77, respectively. The ratio for newborns was 11 % higher than that for adult males. This body size dependency can be explained by the PD response to exposure direction. We discussed the results of this study and our field experiments to construct conversion coefficients from the ADE to the effective doses for age-group residents living in affected areas, which will be presented at the conference. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | International Conference on Individual Monitoring of Ionising Radiation (IM2022) and Neutron and Ion Dosimetry Symposium (NEUDOS-14) | |||||
発表年月日 | ||||||
日付 | 2022-04-28 | |||||
日付タイプ | Issued |