ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Rapid measurement of actinides in urine by mass and alpha spectrometric methods

https://repo.qst.go.jp/records/86506
https://repo.qst.go.jp/records/86506
016db6b3-8ca9-405f-9064-cd4b402a8a8d
Item type 会議発表用資料 / Presentation(1)
公開日 2022-07-08
タイトル
タイトル Rapid measurement of actinides in urine by mass and alpha spectrometric methods
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yang, Guosheng

× Yang, Guosheng

WEKO 1056059

Yang, Guosheng

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 1056060

Eunjoo, Kim

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 1056061

Zheng, Jian

Search repository
Hatsuho, Seno

× Hatsuho, Seno

WEKO 1056062

Hatsuho, Seno

Search repository
Munehiko, Kowatari

× Munehiko, Kowatari

WEKO 1056063

Munehiko, Kowatari

Search repository
Osamu, Kurihara

× Osamu, Kurihara

WEKO 1056064

Osamu, Kurihara

Search repository
Yang, Guosheng

× Yang, Guosheng

WEKO 1056065

en Yang, Guosheng

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 1056066

en Eunjoo, Kim

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 1056067

en Zheng, Jian

Search repository
Hatsuho, Seno

× Hatsuho, Seno

WEKO 1056068

en Hatsuho, Seno

Search repository
Munehiko, Kowatari

× Munehiko, Kowatari

WEKO 1056069

en Munehiko, Kowatari

Search repository
Osamu, Kurihara

× Osamu, Kurihara

WEKO 1056070

en Osamu, Kurihara

Search repository
抄録
内容記述タイプ Abstract
内容記述 In 2017, five workers were involved in the internal contamination accident at a
nuclear facility of the Japan Atomic Energy Agency in Oarai-town, Ibaraki Prefecture, Japan. They accidentally inhaled plutonium compounds (containing Pu and Am isotopes) and the maximum committed effective dose was estimated as a range of 100−200 mSv [1]. Internal contamination with alpha-particle emitting actinides, such as 239Pu, 240Pu, is likely to bring a large amount of dose to the tissues of persons even if the intake amount is small. Therefore, after this accident, medical intervention using decorporation agents (Ca/Zn-DTPA) to patients was performed for the first time in Japan. This chelation therapy was continued for several weeks or months and ca. 200 urinary samples were collected from the five workers before and after each DTPA administration. To cope with similar situations in the future and provide timely information for prompt decision-making in radiation emergency therapy, we are attempting both the optimization of a conventional method based on alpha spectrometry and the development of a screening method based on mass spectrometry [2].
In terms of mass spectrometric method, to eliminate matrix, polyatomic interferences and tailing effects from U, after LaF 3 /CaF 3 coprecipitation, Pu isotopes were collected after removing U effectively (exhibiting a high decontamination factor of 108 for 238U) using a single chromatographic column packed with 2 mL AG MP-1M anion exchange resin. The Pu isotopes were measured using 242 Pu as a yield tracer with yields of 76±5%. Using ICP-MS/MS with low background, very low method detection limits for 239 Pu, 240 Pu, and 241 Pu of 0.057, 0.126, and 76.8 mBq L -1 , respectively, were obtained for 20 mL of urine sample. These detection limits were comparable to those of SF-ICP-MS with higher sensitivity [2].
In terms of alpha spectrometric method, after decomposing organic matter
completely with HNO3 and H2O2 , in order to eliminate matrix and interferences, the combination of the iron hydroxide co-precipitation and the automated separation using the TEVA and DGA resin cartridges was used prior to 48 h counting using alpha spectrometer. This method presented stable and high (~ 80%) yields for Pu, Am, and U, and low method detection limits (< 0.5 mBq using 500 mL urine sample). Subsequently, these alpha and mass spectrometric methods were applied to participate in the intercomparison organized by the Association for the PROmotion of Quality COntrol in RADiotoxicological Analysis (PROCORAD), France, for method validation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Conference on Individual Monitoring of Ionising Radiation (IM2022) and Neutron and Ion Dosimetry Symposium (NEUDOS-14)
発表年月日
日付 2022-04-28
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:46:49.522519
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3