Manual on the proper use of meta-[211At] astato-benzylguanidine ([211At] MABG) injections in clinical trials for targeted alpha therapy
https://repo.qst.go.jp/records/86496
https://repo.qst.go.jp/records/86496920c8a60-e0e0-4acc-b3cb-97456f669b24
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-07-07 | |||||
タイトル | ||||||
タイトル | Manual on the proper use of meta-[211At] astato-benzylguanidine ([211At] MABG) injections in clinical trials for targeted alpha therapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ukon, Naoyuki
× Ukon, Naoyuki× Tatsuya, Higashi× Hosono, Makoto× Kinuya, Seigo× Yamada, Takahiro× Yanagida, Sachiko× Namba, Masao× Nakamura, Yoshihide× Tatsuya, Higashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In this manuscript, we present the guideline for use of meta-[211At] astatobenzylguanidine ([211At] MABG), a newly introduced alpha emitting radiopharmaceutical to the up-coming World’s frst clinical trial for targeted alpha therapy (TAT) at Fukushima Medical University in Japan, focusing on radiation safety issues in Japan. This guideline was prepared based on a study supported by the Ministry of Health, Labour, and Welfare, and approved by the Japanese Society of Nuclear Medicine on Oct. 5th, 2021. The study showed that patients receiving [211At] MABG do not need to be admitted to a radiotherapy room and that TAT using [211At] MABG is possible on an outpatient basis. The radiation exposure from the patient is within the safety standards of the ICRP and IAEA recommendations for the general public and caregivers or patient’s family members. In this guideline, the following contents are also included: precautions for patients and their families, safety management associated with the use of [211At] MABG, education and training, and disposal of medical radioactive contaminants. TAT using [211At] MABG in Japan should be carried out according to this guideline. Although this guideline is based on the medical environment and laws and regulations in Japan, the issues for radiation protection and evaluation methodology presented in this guideline are useful and internationally acceptable as well. |
|||||
書誌情報 |
Annals of Nuclear Medicine 巻 36, p. 695-709, 発行日 2022-06 |
|||||
出版者 | ||||||
出版者 | Springer Nature | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-7187 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12149-022-01765-1 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://trebuchet.public.springernature.app/get_content/cc930489-9ea2-4718-9745-4ff8953ebdab |