Development of ripple filter composed of metal mesh for charged-particle therapy.

https://repo.qst.go.jp/records/86420
https://repo.qst.go.jp/records/86420
4cc1f65a-3a33-4903-a47f-7dcfa22a6cf2
Item type 学術雑誌論文 / Journal Article(1)
公開日 2022-06-30
タイトル
タイトル Development of ripple filter composed of metal mesh for charged-particle therapy.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tanaka, Sodai

× Tanaka, Sodai

WEKO 1056031

Tanaka, Sodai

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 1056032

Inaniwa, Taku

Search repository
Matsuba, Shunya

× Matsuba, Shunya

WEKO 1056033

Matsuba, Shunya

Search repository
Sodai, Tanaka

× Sodai, Tanaka

WEKO 1056034

en Sodai, Tanaka

Search repository
Taku, Inaniwa

× Taku, Inaniwa

WEKO 1056035

en Taku, Inaniwa

Search repository
Shunya, Matsuba

× Shunya, Matsuba

WEKO 1056036

en Shunya, Matsuba

Search repository
抄録
内容記述タイプ Abstract
内容記述 In charged-particle therapy, a ripple filter (RiFi) is used for broadening the Bragg peak in the beam direction. A conventional RiFi consists of plates with a fine ridge and groove structure. The construction of the RiFi has been a time-consuming and costly task. In this study, we developed a simple RiFi made of multi-layered metal mesh (mRiFi), with which the Bragg peak is broadened due to structural randomness, similar to what occurs for the already proposed RiFi with porous material.. The mRiFi was constructed by stacking commercially available metal meshes at random positions and angles. The mRiFi was inexpensive to fabricate due to its high availability and low machining accuracy. The Bragg peak width modulated by the mRiFi can be uniquely determined by the wire material, wire diameter, wire-to-wire spacing of the metal mesh, and the number of mesh sheets. We fabricated four mRiFis consisting of 10, 20, 30, and 40 layers of stainless steel meshes with a wire diameter of 0.1 mm and a wire-to-wire spacing of 0.508 mm.Using the mRiFis consisting of 10, 20, 30, and 40 mesh sheets, we succeeded in broadening the Bragg peak following the normal distribution with the respective standard deviationvalues of 0.83, 1.15, 1.41, and 1.56 mm in water in experimental planar-integrated depth dose measurements with 140.3 MeV ucarbon-ion beams. The effect of range broadening with the mRiFi was independent of its lateral position, and the measurement of the surface dose using radiochromic films showed no severe inhomogeneity with a homogeneity index greater than 0.3 caused by the mRiFis.The developed mRiFi can be used as a RiFi in charged-particle therapy. The mRiFi has three advantages: high supply stability of the material for manufacturing it, easy fabrication, and low cost.
書誌情報 Physics in medicine and biology

巻 67, 号 13, p. NT01, 発行日 2022-06
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
PubMed番号
識別子タイプ PMID
関連識別子 35667368
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/ac762d
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1088/1361-6560/ac762d
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:46:51.629819
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3