ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

In vivo Human MR Spectroscopy Using a Clinical Scanner: Development, Applications, and Future Prospects.

https://repo.qst.go.jp/records/86377
https://repo.qst.go.jp/records/86377
8e4153d8-5e51-4548-827c-28209724be82
Item type 学術雑誌論文 / Journal Article(1)
公開日 2022-06-24
タイトル
タイトル In vivo Human MR Spectroscopy Using a Clinical Scanner: Development, Applications, and Future Prospects.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tomiyasu, Moyoko

× Tomiyasu, Moyoko

WEKO 1058657

Tomiyasu, Moyoko

Search repository
Harada, Masafumi

× Harada, Masafumi

WEKO 1058658

Harada, Masafumi

Search repository
Moyoko, Tomiyasu

× Moyoko, Tomiyasu

WEKO 1058659

en Moyoko, Tomiyasu

Search repository
抄録
内容記述タイプ Abstract
内容記述 MR spectroscopy (MRS) is a unique and useful method for noninvasively evaluating biochemical metabolism in human organs and tissues, but its clinical dissemination has been slow and often limited to specialized institutions or hospitals with experts in MRS technology. The number of 3-T clinical MR scanners is now increasing, representing a major opportunity to promote the use of clinical MRS. In this review, we summarize the theoretical background and basic knowledge required to understand the results obtained with MRS and introduce the general consensus on the clinical utility of proton MRS in routine clinical practice. In addition, we present updates to the consensus guidelines on proton MRS published by the members of a working committee of the Japan Society of Magnetic Resonance in Medicine in 2013. Recent research into multinuclear MRS equipped in clinical MR scanners is explained with an eye toward future development. This article seeks to provide an overview of the current status of clinical MRS and to promote the understanding of when it can be useful. In the coming years, MRS-mediated biochemical evaluation is expected to become available for even routine clinical practice.
書誌情報 Magnetic resonance in medical sciences

巻 21, 号 1, p. 235-252, 発行日 2022-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 1347-3182
PubMed番号
識別子タイプ PMID
関連識別子 35173095
DOI
識別子タイプ DOI
関連識別子 10.2463/mrms.rev.2021-0085
関連サイト
識別子タイプ URI
関連識別子 https://www.jstage.jst.go.jp/article/mrms/21/1/21_rev.2021-0085/_article
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:45:26.394121
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3