The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye
https://repo.qst.go.jp/records/86360
https://repo.qst.go.jp/records/863605d93c53e-df33-4f66-ac61-7dd516087755
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-05-02 | |||||
タイトル | ||||||
タイトル | The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yokoyama, Sumi
× Yokoyama, Sumi× Tsujimura, Norio× Hashimoto, Makoto× Yoshitomi, Hiroshi× Kato, Masahiro× Kurosawa, Tadahiro× Hideo, Tatsuzaki× Sekiguchi, Hiroshi× Koguchi, Yasuhiro× Ono, Koji× Akiyoshi, Masahumi× Kunugita, Naoki× Natsuhori, Masahiro× Natsume, Yoshinori× Nabatame, Kuniaki× Kawashima, Tsunenori× Takagi, Shunji× Ohno, Kazuko× Iwai, Satoshi× Hideo, Tatsuzaki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background In Japan, new regulations that revise the dose limit for the lens of the eye (hereafter the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulation Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set not to exceed the dose limit for the lens. Results and Discussion In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 examples. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion With the development of the guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimize radiation protection. Keywords: New Dose Limit to the Lens of the Eye, Monitoring Guideline, Operational Quantities, Management Criteria, Non-uniform Exposure, Japan Health Physics Society |
|||||
書誌情報 |
Journal of Radiation Protection and Research 巻 47, 号 1, p. 1-7, 発行日 2022-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 250 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.14407/jrpr.2021.00276 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.14407/jrpr.2021.00276 |