WEKO3
アイテム
Super-resolution generative adversarial networks with static T2*WI-based subject-specific learning to improve spatial difference sensitivity in fMRI activation.
https://repo.qst.go.jp/records/86355
https://repo.qst.go.jp/records/86355090213b7-17d6-40be-aebf-22878482dd36
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-06-20 | |||||
タイトル | ||||||
タイトル | Super-resolution generative adversarial networks with static T2*WI-based subject-specific learning to improve spatial difference sensitivity in fMRI activation. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Junko, Ota
× Junko, Ota× Kensuke, Umehara× Kershaw, Jeffrey× Riwa, Kishimoto× Yoshiyuki, Hirano× Yasuhiko, Tachibana× Hisateru, Ohba× Takayuki, Obata× Junko, Ota× Kensuke, Umehara× Kershaw, Jeffrey× Riwa, Kishimoto× Yoshiyuki, Hirano× Yasuhiko, Tachibana× Hisateru, Ohba× Takayuki, Obata |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The spatial resolution of fMRI is relatively poor and improvements are needed to indicate more specific locations for functional activities. Here, we propose a novel scheme, called Static T2*WI-based Subject-Specific Super Resolution fMRI (STSS-SRfMRI), to enhance the functional resolution, or ability to discriminate spatially adjacent but functionally different responses, of fMRI. The scheme is based on super-resolution generative adversarial networks (SRGAN) that utilize a T2*-weighted image (T2*WI) dataset as a training reference. The efficacy of the scheme was evaluated through comparison with the activation maps obtained from the raw unpreprocessed functional data (raw fMRI). MRI images were acquired from 30 healthy volunteers using a 3 Tesla scanner. The modified SRGAN reconstructs a high-resolution image series from the original low-resolution fMRI data. For quantitative comparison, several metrics were calculated for both the STSS-SRfMRI and the raw fMRI activation maps. The ability to distinguish between two different finger-tapping tasks was significantly higher [p = 0.00466] for the reconstructed STSS-SRfMRI images than for the raw fMRI images. The results indicate that the functional resolution of the STSS-SRfMRI scheme is superior, which suggests that the scheme is a potential solution to realizing higher functional resolution in fMRI images obtained using 3T MRI. | |||||
書誌情報 |
Scientific Reports 巻 12, 号 10319, p. 1-9, 発行日 2022-06 |
|||||
出版者 | ||||||
出版者 | Nature Publishing Group | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2045-2322 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 35725788 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1038/s41598-022-14421-5 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.nature.com/articles/s41598-022-14421-5 |