Estimation of biological effect of Cu-64 radiopharmaceuticals with Geant4-DNA simulation
https://repo.qst.go.jp/records/86220
https://repo.qst.go.jp/records/86220f98fbb81-b1e7-4bfa-84cd-7c87edc0e6fc
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-05-31 | |||||
タイトル | ||||||
タイトル | Estimation of biological effect of Cu-64 radiopharmaceuticals with Geant4-DNA simulation | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tamon, Kusumoto
× Tamon, Kusumoto× Baba, Kentaro× Sumitaka, Hasegawa× Raffy, Quentin× Satoshi, Kodaira× Tamon, Kusumoto× Sumitaka, Hasegawa× Satoshi, Kodaira |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The aim of this work is to estimate the biological effect of targeted radionuclide therapy using Cu-64, which is a well-known Auger electron emitter. To do so, we evaluate the absorbed dose of emitted particles from Cu-64 using the Geant4-DNA Monte Carlo simulation toolkit. The contribution of beta particles to the absorbed dose is higher than that of Auger electrons. The simulation result agrees with experimental ones evaluated using coumarin-3-carboxylic acid chemical dosimeter. The simulation result is also in good agreement with previous ones obtained using fluorescent nuclear track detector. From the results of present simulation (i.e., absorbed dose estimation) and previous biological experiments using two cell lines (i.e., evaluation of survival curves), we have estimated the relative biological effectiveness (RBE) of Cu-64 emitted particles on CHO wild-type cells and xrs5 cells. The RBE of xrs5 cells exposed to Cu-64 is almost equivalent to that with gamma rays and protons and C ions. This result indicates that the radiosensitivity of xrs5 cells is independent of LET. In comparison to this, the RBE on CHO wild-type cells exposed to Cu-64 is significantly higher than gamma rays and almost equivalent to that irradiated with C ions with a linear energy transfer of 70 keV/μm. | |||||
書誌情報 |
Scientific Reports 巻 12, p. 8957, 発行日 2022-05 |
|||||
出版者 | ||||||
出版者 | Nature Research | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2045-2322 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1038/s41598-022-13096-2 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1038/s41598-022-13096-2 |