WEKO3
アイテム
Diamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement
https://repo.qst.go.jp/records/85693
https://repo.qst.go.jp/records/85693cc8869f6-4e1a-4638-adf0-189042462142
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-10-07 | |||||
タイトル | ||||||
タイトル | Diamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Zhang, Chen
× Zhang, Chen× Shagieva, Farida× Widmann, Matthias× Michael, Kübler× Vorobyov, Vadim× Kapitanova, Polina× Nenasheva, Elizaveta× Corkill, Ruth× Rhrle, Oliver× Nakamura, Kazuo× Sumiya, Hitoshi× Shinobu, Onoda× Junichi, Isoya× Jörg, Wrachtrup× Shinobu, Onoda× Junichi, Isoya |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Nitrogen-vacancy (N-V) centers in diamond have developed into a powerful solid-state platform for compact quantum sensors. However, high-sensitivity measurements usually come with additional constraints on the pumping intensity of the laser and the pulse control applied. Here, we demonstrate high-sensitivity N-V-ensemble-based magnetic field measurements with low-intensity optical excitation. Direct current magnetometry methods such as continuous-wave optically detected magnetic resonance and continuously excited Ramsey measurements combined with lock-in detection are compared to achieve an optimization. Gradiometry is also investigated as a step towards unshielded measurements of unknown gradients. The magnetometer demonstrates a minimum detectable field of 0.3–0.7 pT in a 73-s measurement when a flux guide with a sensing dimension of 2 mm is applied, corresponding to a magnetic field sensitivity of 2.6–6 pT/√Hz. Combined with our previous efforts on diamond ac magnetometry, the diamond magnetometer is promising for performing wide-bandwidth magnetometry with picotesla sensitivity and a cubic-millimeter sensing volume under ambient conditions. | |||||
書誌情報 |
PHYSICAL REVIEW APPLIED 巻 15, 号 6, p. 064075, 発行日 2021-06 |
|||||
出版者 | ||||||
出版者 | APS | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2331-7019 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1103/PhysRevApplied.15.064075 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://journals.aps.org/prapplied/abstract/10.1103/PhysRevApplied.15.064075 |