WEKO3
アイテム
Chemical compatibility of F82H and 316L in liquid metal heat transfer mediums Li, Na and NaK
https://repo.qst.go.jp/records/85639
https://repo.qst.go.jp/records/856392267ed08-05a0-4026-97a8-f3903012ac6b
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-02-21 | |||||
タイトル | ||||||
タイトル | Chemical compatibility of F82H and 316L in liquid metal heat transfer mediums Li, Na and NaK | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hosaka, Tatsuhiro
× Hosaka, Tatsuhiro× Kondo, Masatoshi× Satoshi, Sato× Masami, Ando× Takashi, Nozawa× Satoshi, Sato× Masami, Ando× Takashi, Nozawa |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Liquid metals Li, Na and NaK are the candidate heat transfer mediums which are installed in the ir- radiation capsule of advanced fusion neutron source. The compatibility issue of F82H and 316L in the candidate heat transfer mediums was studied by means of the corrosion tests at the temperature up to 823 K. The depletion of Cr, C and Fe from the steel was caused in liquid Li. The Li diffusion into the steel matrix was analyzed by TOF-SIMS. The corrosion in liquid Na was caused by the Na diffusion into the steel matrix and the surface oxidation. The corrosion in NaK was similar with that in liquid Na. | |||||
書誌情報 |
Journal of Nuclear Materials 巻 561, p. 153546, 発行日 2022-01 |
|||||
出版者 | ||||||