Measurement of radon concentration in water using a radon-in-air monitor

https://repo.qst.go.jp/records/85332
https://repo.qst.go.jp/records/85332
0d8ce368-dd54-404b-9164-36f42fc52d7b
Item type 会議発表論文 / Conference Paper(1)
公開日 2021-12-20
タイトル
タイトル Measurement of radon concentration in water using a radon-in-air monitor
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takakaze, Yui

× Takakaze, Yui

WEKO 1028498

Takakaze, Yui

Search repository
Yasuoka, Yumi

× Yasuoka, Yumi

WEKO 1028499

Yasuoka, Yumi

Search repository
Higuchi, Shoko

× Higuchi, Shoko

WEKO 1028500

Higuchi, Shoko

Search repository
Matsumoto, Maho

× Matsumoto, Maho

WEKO 1028501

Matsumoto, Maho

Search repository
Hosoda, Masahiro

× Hosoda, Masahiro

WEKO 1028502

Hosoda, Masahiro

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 1028503

Tokonami, Shinji

Search repository
Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 1028504

Iwaoka, Kazuki

Search repository
Mukai, Takahiro

× Mukai, Takahiro

WEKO 1028505

Mukai, Takahiro

Search repository
Kazuki, Iwaoka

× Kazuki, Iwaoka

WEKO 1028506

en Kazuki, Iwaoka

Search repository
抄録
内容記述タイプ Abstract
内容記述 The World Health Organization recommends that the radon concentration in water should be no more than 100 Bq L−1 as the WHO guideline value. In this study, two types of degassing systems, i.e. RAD H2O and AquaKIT, respectively, connecting to a radon-in-air monitor were applied to measure radon concentrations in water, and this technique was compared to a liquid scintillation counter method as the reference. In order to judge whether RAD7 with those two degassing systems were applicable as a screening method, the criterion was investigated. The two degassing methods were found to be effective as the screening method with the WHO guideline value. Moreover, a system whose screening test value is closer to the guideline value is more effective as a screening device. The screening values of RAD H2O and AquaKIT were 86 and 92 Bq L−1, respectively. We conclude that the AquaKIT can be recommended as the degassing system when performing the degassing method
書誌情報 Proceedings of the 22nd workshop on environmental radioactivity

巻 KEK proceedings 2021-2, p. 118-124, 発行日 2021-12
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:02:03.455311
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3