A simple and rapid method for analysis of Pu isotopes in steel and concrete samples by SF-ICP-MS with a single column chromatography separation

https://repo.qst.go.jp/records/85330
https://repo.qst.go.jp/records/85330
98b3a270-66e3-44c4-b14b-c15898596307
Item type 会議発表論文 / Conference Paper(1)
公開日 2021-12-17
タイトル
タイトル A simple and rapid method for analysis of Pu isotopes in steel and concrete samples by SF-ICP-MS with a single column chromatography separation
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Zhang, Shuai

× Zhang, Shuai

WEKO 1028480

Zhang, Shuai

Search repository
Yang, Guosheng

× Yang, Guosheng

WEKO 1028481

Yang, Guosheng

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 1028482

Zheng, Jian

Search repository
Tatsuo, Aono

× Tatsuo, Aono

WEKO 1028483

Tatsuo, Aono

Search repository
Pan, Shaoming

× Pan, Shaoming

WEKO 1028484

Pan, Shaoming

Search repository
Zhang, Shuai

× Zhang, Shuai

WEKO 1028485

en Zhang, Shuai

Search repository
Yang, Guosheng

× Yang, Guosheng

WEKO 1028486

en Yang, Guosheng

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 1028487

en Zheng, Jian

Search repository
Tatsuo, Aono

× Tatsuo, Aono

WEKO 1028488

en Tatsuo, Aono

Search repository
抄録
内容記述タイプ Abstract
内容記述 In this study, a simple and rapid method was developed to analyze Pu in steel and concrete samples. HCl−HNO3−NH4HF2 digestion system was used for the total digestion of steel and concrete samples, CaF2/LaF3 co-precipitation was used to remove matrix, and a single anion-exchange (AG MP-1M) chromatography was used for chemical separation of Pu isotopes. Finally, the Pu was analyzed by SF-ICP-MS using an APEX-Q/ACM sample introduction system. The whole analytical process can be completed within 1 day, and the results show that the most of matrix elements were removed, which have a tiny influence on the separation efficiency of Pu in the resin column with the Pu recovery of 84 ± 6% and 71 ± 4% in the steel sample and steel + concrete samples, respectively. In addition, the main interfering element U was almost completely removed with high decontamination factors of 1.1  106. The LODs of 239Pu and 240Pu were 0.22fg g-1 and 0.25fg g-1, respectively, allowing us to effectively detect low level Pu contamination in steel and concrete samples.
書誌情報 Proceedings of the 22th KEK Symposium on Environmental Radioactivity

p. 135-139, 発行日 2021-12
出版者
出版者 High Energy accelerator Research Organization (KEK)
関連サイト
識別子タイプ URI
関連識別子 https://jpn01.safelinks.protection.outlook.com/?url=https%3A%2F%2Flib-extopc.kek.jp%2Fpreprints%2FPDF%2F2021%2F2125%2F2125002.pdf&data=04%7C01%7Czheng.jian%40qst.go.jp%7C1762384f4f024047960708d9c094cae7%7C6ca85328a4904ba08df9d0b978df06cd%7C0%7C0%7C637752567566682759%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C3000&sdata=dW%2Fh1ZtF%2Fj2%2B7UprSmFYlNYSMr0HyytwIMyYCT0vGDk%3D&reserved=0
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:02:04.818920
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3