WEKO3
アイテム
Shear wave speed measurement bias in a viscoelastic phantom across six ultrasound elastography systems: a comparative study with transient elastography and magnetic resonance elastography
https://repo.qst.go.jp/records/85236
https://repo.qst.go.jp/records/85236f6c0b970-aa58-4011-834d-a3defbabd1c1
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-03-14 | |||||
タイトル | ||||||
タイトル | Shear wave speed measurement bias in a viscoelastic phantom across six ultrasound elastography systems: a comparative study with transient elastography and magnetic resonance elastography | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Riwa, Kishimoto
× Riwa, Kishimoto× Suga, Mikio× Usumura, Masashi× Iijima, Hiroko× Masahiro, Yoshida× Hachiya, Hiroyuki× Shiina, Tsuyoshi× Yamakawa, Makoto× Konno, Kei× Takayuki, Obata× Yamaguchi, Tadashi× Riwa, Kishimoto× Mikio, Suga× Masashi, Usumura× Masahiro, Yoshida× Takayuki, Obata |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose To quantify the bias of shear wave speed (SWS) measurements in a viscoelastic phantom across six different ultrasound (US) systems and to compare the SWS with those from transient elastography (TE) and magnetic resonance elastography (MRE). Methods A viscoelastic phantom of stiffness representing fibrotic liver or healthy thyroid was measured with nine (linear probe) and 10 (convex probe) modes of six different US-based shear wave elastography (SWE) systems using linear and convex probes. SWS measurements of three regions of interest were repeated thrice at two focal depths, coupling the probe to the phantom using a jig. An MRE system using three motion-encoding gradient frequencies of 60, 90, and 120 Hz and TE were also used to measure the stiffness of the phantom. Results The SWS from different SWE systems had mean coefficients of variation of 9.0–9.2% and 5.4–5.6% with linear and convex probes, respectively, in viscoelastic phantom measurement. The focal depth was a less significant source of SWS variability than the system. The total average SWS obtained with US-SWE systems was 19.9% higher than that obtained with MRE at 60 Hz, which is commonly used in clinical practice, and 31.5% higher than that obtained with TE using the M probe. Conclusions Despite the measurement biases associated with the SWE systems, biases were not necessarily consistent, and they changed with the probes used and depth measured. The SWS of the viscoelastic phantom obtained using different modalities increased according to the shear wave frequency used. |
|||||
書誌情報 |
Journal of Medical Ultrasonics 巻 49, 号 2, p. 143-152, 発行日 2022-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1346-4523 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 35061118 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s10396-022-01190-x | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://link.springer.com/article/10.1007/s10396-022-01190-x |