ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

An Analysis Scheme for 3D Visualization of Positron Emitting Radioisotopes Using Positron Emission Mammography System

https://repo.qst.go.jp/records/85179
https://repo.qst.go.jp/records/85179
dc911fb6-d5ea-4ae8-9128-ff681cc6777f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2022-01-19
タイトル
タイトル An Analysis Scheme for 3D Visualization of Positron Emitting Radioisotopes Using Positron Emission Mammography System
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Rafiqul Islam, Md.

× Rafiqul Islam, Md.

WEKO 1026761

Rafiqul Islam, Md.

Search repository
Shahmohammadi Beni, Mehrdad

× Shahmohammadi Beni, Mehrdad

WEKO 1026762

Shahmohammadi Beni, Mehrdad

Search repository
Shigeki, Ito

× Shigeki, Ito

WEKO 1026763

Shigeki, Ito

Search repository
Gotoh, Shinichi

× Gotoh, Shinichi

WEKO 1026764

Gotoh, Shinichi

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1026765

Taiga, Yamaya

Search repository
Watabe, Hiroshi

× Watabe, Hiroshi

WEKO 1026766

Watabe, Hiroshi

Search repository
Shigeki, Ito

× Shigeki, Ito

WEKO 1026767

en Shigeki, Ito

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1026768

en Taiga, Yamaya

Search repository
抄録
内容記述タイプ Abstract
内容記述 Proton range monitoring and verification is important to enhance the effectiveness of treatment by ensuring that the correct dose is delivered to the correct location. Upon proton irradiation, different positron emitting radioisotopes are produced by the inelastic nuclear interactions of protons
with the target elements. Recently, it was reported that the 16O(p,2p2n)13N reaction has a relatively low threshold energy, and it could be potentially used for proton range verification. In the present work, we have proposed an analysis scheme (i.e., algorithm) for the extraction and three-dimensional
visualization of positron emitting radioisotopes. The proposed step-by-step analysis scheme was tested using our own experimentally obtained dynamic data from a positron emission mammography (PEM) system (our developed PEMGRAPH system). The experimental irradiation was performed using an azimuthally varying field (AVF) cyclotron with a 80 MeV monoenergetic pencil-like beam. The 3D visualization showed promising results for proton-induced radioisotope distribution. The proposed scheme and developed tools would be useful for the extraction and 3D visualization of positron emitting radioisotopes and in turn for proton range monitoring and verification.
書誌情報 Applied Sciences

巻 12, 号 2, p. 823, 発行日 2022-01
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 2076-3417
DOI
識別子タイプ DOI
関連識別子 10.3390/app12020823
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.3390/app12020823
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:03:17.992905
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3