CO2 concentration visualization for COVID-19 infection prevention in concert halls

https://repo.qst.go.jp/records/85165
https://repo.qst.go.jp/records/85165
86aa24c7-2604-4c16-9e26-02ece9f74158
Item type 学術雑誌論文 / Journal Article(1)
公開日 2022-03-10
タイトル
タイトル CO2 concentration visualization for COVID-19 infection prevention in concert halls
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kitamura, Hiroko

× Kitamura, Hiroko

WEKO 1036324

Kitamura, Hiroko

Search repository
Ishigaki, Yo

× Ishigaki, Yo

WEKO 1036325

Ishigaki, Yo

Search repository
Kuriyama, Tomoko

× Kuriyama, Tomoko

WEKO 1036326

Kuriyama, Tomoko

Search repository
Takashi, Moritake

× Takashi, Moritake

WEKO 1036327

Takashi, Moritake

Search repository
Takashi, Moritake

× Takashi, Moritake

WEKO 1036328

en Takashi, Moritake

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objectives: For preventing coronavirus disease 2019 (COVID-19) clusters, avoiding the three C’s, which are closed spaces with poor ventilation, crowded places with many people, and close contact for conversation, is important. The CO2 concentration in a room indicates the ventilation status, number of persons present in the room, and their kinetic strength or activity intensity. The real-time monitoring of CO2 concentration in a room will enable instantaneously confirming whether ventilation is sufficient. Methods: This study investigated monitoring CO2 concentration in real time during a concert and instantly indicating the measurement results on a display. Results: The average CO2 concentration during the performance was confirmed to be 505.6 ppm with the maximum value 575 ppm, and these values were in line with the estimated value given by the Ventilation Simulator designed by the Occupational Hygiene and Ergonomics Section of the Japan Society for Occupational Health. The CO2 concentration visualization has the benefit of providing a sense of security to the concert audience, musicians, and concert organizing staff during the performance. Conclusion: For preventing COVID-19 clusters, it is important to take multiple and comprehensive countermeasures considering concert event-specific infection routes; visualizing CO2 concentration is one effective preventative measure against airborne (droplet nuclei) infection. The CO2 concentration visualization based on prior estimation is expected to become part of the standard operational procedure of concert venues.
書誌情報 Environmental and Occupational Health Practice

巻 3, 号 1, 発行日 2021-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 2434-4931
DOI
識別子タイプ DOI
関連識別子 10.1539/eohp.2021-0010-OA
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:56:31.956928
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3