ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Japanese structure survey of radiation oncology in 2015.

https://repo.qst.go.jp/records/85138
https://repo.qst.go.jp/records/85138
10bc2949-2984-4291-8fb7-5b6ce0aa0811
Item type 学術雑誌論文 / Journal Article(1)
公開日 2022-03-09
タイトル
タイトル Japanese structure survey of radiation oncology in 2015.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hodaka, Numasaki

× Hodaka, Numasaki

WEKO 1043495

Hodaka, Numasaki

Search repository
Yoshihiro, Nakada

× Yoshihiro, Nakada

WEKO 1043496

Yoshihiro, Nakada

Search repository
Yasuo, Okuda

× Yasuo, Okuda

WEKO 1043497

Yasuo, Okuda

Search repository
Hisateru, Ohba

× Hisateru, Ohba

WEKO 1043498

Hisateru, Ohba

Search repository
Teshima, Teruki

× Teshima, Teruki

WEKO 1043499

Teshima, Teruki

Search repository
Ogawa, Kazuhiko

× Ogawa, Kazuhiko

WEKO 1043500

Ogawa, Kazuhiko

Search repository
Hodaka, Numasaki

× Hodaka, Numasaki

WEKO 1043501

en Hodaka, Numasaki

Search repository
Yoshihiro, Nakada

× Yoshihiro, Nakada

WEKO 1043502

en Yoshihiro, Nakada

Search repository
Yasuo, Okuda

× Yasuo, Okuda

WEKO 1043503

en Yasuo, Okuda

Search repository
Hisateru, Ohba

× Hisateru, Ohba

WEKO 1043504

en Hisateru, Ohba

Search repository
抄録
内容記述タイプ Abstract
内容記述 This article describes the ongoing structure of radiation oncology in Japan in terms of equipment, personnel, patient load and geographic distribution to identify and overcome any existing limitations. From May 2016 to August 2018, the Japanese Society for Radiation Oncology conducted a questionnaire based on the Japanese national structure survey of radiation oncology in 2015. Data were analyzed based on the institutional stratification by the annual number of new patients treated with radiotherapy per institution. The estimated annual numbers of new and total (new plus repeat) patients treated with radiation were 225 000 and 271 000, respectively. Additionally, the estimated cancer incidence was 891 445 cases with approximately 25.2% of all newly diagnosed patients being treated with radiation. The types and numbers of treatment devices actually used included linear accelerator (linac; n = 936), Gamma Knife (n = 43), 60Co remote afterloading system (RALS; n = 21), and 192Ir RALS (n = 129). The linac system used dual-energy functions in 754 units, 3D conformal radiotherapy functions in 867, and intensity-modulated radiotherapy (IMRT) functions in 628. There were 899 Japan Radiological Society/Japanese Society for Radiation Oncology-certified radiation oncologists (RO), 1213.9 full-time equivalent (FTE) ROs, 2394.2 FTE radiotherapy technologists (RTT), 295.7 FTE medical physicists, 210.2 FTE radiotherapy quality managers, and 906.1 FTE nurses. The frequency of IMRT use significantly increased during this time. In conclusion, the Japanese structure of radiation oncology has clearly improved in terms of equipment and utility although there was a shortage of personnel in 2015.
書誌情報 Journal of Radiation Research

巻 63, 号 2, p. 230-246, 発行日 2022-02
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 1349-9157
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rrab129
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1093/jrr/rrab129
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:53:13.591956
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3