ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Simulation evaluation on a compact monitor for gamma-emitting tracers in plant stems

https://repo.qst.go.jp/records/85032
https://repo.qst.go.jp/records/85032
840caec7-79cd-44fc-922a-1ab04ff3d80d
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-12-23
タイトル
タイトル Simulation evaluation on a compact monitor for gamma-emitting tracers in plant stems
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mitsutaka, Yamaguchi

× Mitsutaka, Yamaguchi

WEKO 1025422

Mitsutaka, Yamaguchi

Search repository
Nobuo, Suzui

× Nobuo, Suzui

WEKO 1025423

Nobuo, Suzui

Search repository
Yuuto, Nagao

× Yuuto, Nagao

WEKO 1025424

Yuuto, Nagao

Search repository
Naoki, Kawachi

× Naoki, Kawachi

WEKO 1025425

Naoki, Kawachi

Search repository
Mitsutaka, Yamaguchi

× Mitsutaka, Yamaguchi

WEKO 1025426

en Mitsutaka, Yamaguchi

Search repository
Nobuo, Suzui

× Nobuo, Suzui

WEKO 1025427

en Nobuo, Suzui

Search repository
Yuuto, Nagao

× Yuuto, Nagao

WEKO 1025428

en Yuuto, Nagao

Search repository
Naoki, Kawachi

× Naoki, Kawachi

WEKO 1025429

en Naoki, Kawachi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Non-destructive monitoring of radioactivities derived from radioactive tracers at multiple points in plant stems can be used to evaluate the velocity of element transport in living plants. In this study, we calculated absorption-efficiency distributions for several detector geometries to determine appropriate shapes for non-destructive monitoring of radioactivities in the stem. The efficiency distributions were calculated by Monte Carlo simulations, and the flatnesses and spatial resolutions were evaluated. It was found that the placement of four detectors around the stem could limit the percentage of standard deviation to the mean of the pixel values to less than 5%. We could determine a compact detector geometry with the spatial resolution of 1.35 cm using four small detectors. The detection efficiencies were 0.014, 0.0030 and 0.00063 cm at the initial gamma-ray energies of 0.5, 1 and 2 MeV, which is sufficiently applicable to detect 10 kBq/cm of radioactivity.
書誌情報 Japanese Journal of Applied Physics

巻 61, 号 2, p. 027001, 発行日 2021-12
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 0021-4922
DOI
識別子タイプ DOI
関連識別子 10.35848/1347-4065/ac44b2
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.35848/1347-4065/ac44b2
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:04:43.787744
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3