ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Estimation of the local concentration of the markedly dense hydroxyl radical generation induced by X-rays in water

https://repo.qst.go.jp/records/84961
https://repo.qst.go.jp/records/84961
621dc548-db22-4e36-b525-eb1e29b19bfe
名前 / ファイル ライセンス アクション
6bbde891aaf811a3c1d18dd37dd56166.pdf Matsumoto.K.2022.Molecules.27(3).592.pdf (3.4 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-11-24
タイトル
タイトル Estimation of the local concentration of the markedly dense hydroxyl radical generation induced by X-rays in water
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ken-ichiro, Matsumoto

× Ken-ichiro, Matsumoto

WEKO 1040952

Ken-ichiro, Matsumoto

Search repository
Ueno, Megumi

× Ueno, Megumi

WEKO 1040953

Ueno, Megumi

Search repository
Shoji, Yoshimi

× Shoji, Yoshimi

WEKO 1040954

Shoji, Yoshimi

Search repository
Nakanishi, Ikuo

× Nakanishi, Ikuo

WEKO 1040955

Nakanishi, Ikuo

Search repository
Kenichiro, Matsumoto

× Kenichiro, Matsumoto

WEKO 1040956

en Kenichiro, Matsumoto

Search repository
Megumi, Ueno

× Megumi, Ueno

WEKO 1040957

en Megumi, Ueno

Search repository
Yoshimi, Shoji

× Yoshimi, Shoji

WEKO 1040958

en Yoshimi, Shoji

Search repository
Ikuo, Nakanishi

× Ikuo, Nakanishi

WEKO 1040959

en Ikuo, Nakanishi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The density of X-ray-induced markedly dense hydroxyl radicals (•OH) in water was estimated based on EPR spin-trapping measurement using DMPO as the spin-trapping agent. A lower (0.13 mM‒2.3 M) concentration series of DMPO water solutions and higher (1.7‒4.8 M) concentration series of DMPO water solutions plus neat DMPO liquid (8.8 M as DMPO) were irradiated with 32 Gy of X-rays. Then, the yield of DMPO-OH in DMPO water solutions and the total spin-adduct of DMPO in neat DMPO were quantified. Estimating the EPR signal peak area by the line fitting method is only available for well-separated single EPR lines. For the higher concentration DMPO series, the EPR signal peak area was estimated by double integration. The baseline correction of the integral spectrum is necessary for accurate estimation of the double integration of EPR spectrum. In addition, using the suitable standard sample corresponding to the EPR sensitivity, which was variable by the electric permittivity according to DMPO concentration, was quite important for quantification of DMPO-OH especially in the higher DMPO concentration beyond 2 mM. The local density of •OH generation in water by X-ray irradiation was estimated from the inflection point on the plot of the DMPO-OH yield versus DMPO density. The density of X-ray-induced markedly dense •OH was estimated as 1184 μm-1, which was converted to 0.84 nm as the intermolecular distance and 2.8 M as the local concentration.
書誌情報 Molecules

巻 27, 号 3, p. 592, 発行日 2022-01
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 1420-3049
PubMed番号
識別子タイプ PMID
関連識別子 35163857
DOI
識別子タイプ DOI
関連識別子 10.3390/molecules27030592
関連サイト
識別子タイプ URI
関連識別子 https://www.mdpi.com/1420-3049/27/3/592
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:54:26.409614
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3