ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Evaluation of the Correction Methods Using Age and BMI for Estimating CT Organ Dose Using a Radiophotoluminescence Glass Dosimeter and a Monte Carlo-based Dose Calculator

https://repo.qst.go.jp/records/84921
https://repo.qst.go.jp/records/84921
817c53bf-22b0-4def-91fb-35a8b75abb26
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-12-28
タイトル
タイトル Evaluation of the Correction Methods Using Age and BMI for Estimating CT Organ Dose Using a Radiophotoluminescence Glass Dosimeter and a Monte Carlo-based Dose Calculator
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Chang, Weishan

× Chang, Weishan

WEKO 1024176

Chang, Weishan

Search repository
Yusuke, Koba

× Yusuke, Koba

WEKO 1024177

Yusuke, Koba

Search repository
Chang, Weishan

× Chang, Weishan

WEKO 1024178

en Chang, Weishan

Search repository
Yusuke, Koba

× Yusuke, Koba

WEKO 1024179

en Yusuke, Koba

Search repository
抄録
内容記述タイプ Abstract
内容記述 The size-specific dose estimates (SSDE) have been recommended to replace the volume computed tomography dose index (CTDIvol) because it takes patient size into account. On the other hand, organ dose is thought to be a more appropriate quantity in the radiation protection field due to its correlation with radiation risk. The web-based computed tomography (CT) dose calculator WAZA-ARIv2 only offers organ doses for adults with four different body shapes and for children with five different ages. Since the American Association of Physicists in Medicine (AAPM) offers the conversion factors for SSDE and the correlation of SSDE with organ dose has been demonstrated, implementation of the conversion table might improve the accuracy of WAZA-ARIv2. This study aimed to evaluate a body mass index (BMI)-based and age-based correction method for estimation of the organ dose by using a radiophotoluminescence dosimeter (RGD), an anthropomorphic phantom, and the dose calculator WAZA-ARIv2. RGDs were individually calibrated by using an ISOVOLT TITAN-320 x-ray generator. The ratio of the SSDE conversion factors (CFSSDE) was used as the comparison index. For the BMI-based correction method, the ratio of CFSSDE values for the adult phantoms was expected to be 1.065, and the average ratio of the organ doses for the adult phantoms was 1.163 ± 0.169. For the age-based correction method, the ratio of CFSSDE value for 5- and 10-y-old pediatric phantoms was expected to be 0.889, and the ratios of the organ doses were 0.866 ± 0.024 and 0.909 ± 0.047 for the WAZA-ARIv2 dosimetry system and RGD dosimetry system, respectively. In conclusion, both evaluations of the experimental results showed the consistency between WAZA-ARIv2 and the SSDE conversion factor table. Moreover, the importance of taking the measurement position into account when applying the mass attenuation coefficient was demonstrated according to this study.
書誌情報 Health Physics

巻 121, 号 5, p. 463-470, 発行日 2021-12
出版者
出版者 Health Physics Society
ISSN
収録物識別子タイプ ISSN
収録物識別子 0017-9078
DOI
識別子タイプ DOI
関連識別子 10.1097/HP.0000000000001460
関連サイト
識別子タイプ URI
関連識別子 https://journals.lww.com/health-physics/Fulltext/2021/11000/Evaluation_of_the_Correction_Methods_Using_Age_and.3.aspx
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:06:04.595217
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3