ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Using inverse Laplace transform in positronium lifetime imaging

https://repo.qst.go.jp/records/84895
https://repo.qst.go.jp/records/84895
0a6b0572-47c3-4559-9b27-92e3cf9836dd
Item type 学術雑誌論文 / Journal Article(1)
公開日 2022-02-14
タイトル
タイトル Using inverse Laplace transform in positronium lifetime imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kengo, Shibuya

× Kengo, Shibuya

WEKO 1036471

Kengo, Shibuya

Search repository
Saito, Haruo

× Saito, Haruo

WEKO 1036472

Saito, Haruo

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 1036473

Hideaki, Tashima

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1036474

Taiga, Yamaya

Search repository
Kengo, Shibuya

× Kengo, Shibuya

WEKO 1036475

en Kengo, Shibuya

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 1036476

en Hideaki, Tashima

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1036477

en Taiga, Yamaya

Search repository
抄録
内容記述タイプ Abstract
内容記述 Positronium (Ps) lifetime imaging is gaining attention to bring out additional biomedical information from positron emission tomography (PET). The lifetime of Ps in vivo can change depending on the physical and chemical environments related to some diseases. Due to the limited sensitivity, Ps lifetime imaging may require merging some voxels for statistical accuracy. This paper presents a method for separating the lifetime components in the voxel to avoid information loss due to averaging. The mathematics for this separation is the inverse Laplace transform (ILT), and the authors examined an iterative numerical ILT algorithm using Tikhonov regularization, namely CONTIN, to discriminate a small lifetime difference due to oxygen saturation. The separability makes it possible to merge voxels without missing critical information on whether they contain abnormally long or short lifetime components. The authors conclude that ILT can compensate for the weaknesses of Ps lifetime imaging and extract the maximum amount of information.
書誌情報 Physics in Medicine & Biology

巻 67, 号 2, p. 025009, 発行日 2022-02
出版者
出版者 IOP Science
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/ac499b
関連サイト
識別子タイプ URI
関連識別子 https://iopscience.iop.org/article/10.1088/1361-6560/ac499b
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:56:27.512045
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3