WEKO3
アイテム
Enhancing the accumulation level of 3-[18F]fluoro-L-α-methyltyrosine in tumors by preloading probenecid
https://repo.qst.go.jp/records/84834
https://repo.qst.go.jp/records/84834bfd96802-60d7-4a01-bc96-f5a853611886
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-09-21 | |||||
タイトル | ||||||
タイトル | Enhancing the accumulation level of 3-[18F]fluoro-L-α-methyltyrosine in tumors by preloading probenecid | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ayaka, Kanai
× Ayaka, Kanai× Hirofumi, Hanaoka× Aiko, Yamaguchi× Isa, Manhendra× Citra, Palangka× Yasuhiro, Oshima× Tetsuya, Higuchi× Yoshito, Tsushima× Yasuhiro, Oshima |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Introduction: 3-[18F]fluoro-α-methyl-L-tyrosine ([18F]FAMT) is a promising amino acid tracer targeting L-type amino acid transporter 1 (LAT1). One concern regarding the diagnosis using [18F]FAMT is the possibility of false-negative findings because of its relatively low accumulation level even in malignant tumors. Moreover, preloading probenecid, an organic anion transporter inhibitor, markedly increased the tumor accumulation level of radioiodine-labeled α-methyltyrosine. In this study, we evaluated the usefulness of preloading probenecid in improving the tumor-imaging capability of [18F]FAMT. Methods: Three biodistribution studies of [18F]FAMT were conducted in normal mice to elucidate the usefulness of probenecid preloading. Then, a biodistribution study and positron emission tomography (PET) imaging of [18F]FAMT were conducted with or without probenecid injection in tumor-bearing mice. Results: Probenecid preloading significantly delayed blood clearance and consequently enhanced the accumulation of [18F]FAMT in the pancreas, a LAT1-positive organ. The effects of probenecid preloading were independent of the administration route. Tumor accumulation level in the biodistribution study and the maximum standardized uptake value in tumors on PET imaging of the probenecid preloading group were significantly higher than those of the control (without probenecid injection) group in tumor-bearing mice. Conclusions: Preloading probenecid significantly delayed blood clearance and consequently enhanced the accumulation of [18F]FAMT in tumors. These results indicate that preloading probenecid could improve the diagnostic accuracy of [18F]FAMT. |
|||||
書誌情報 |
Nuclear Medicine and Biology 巻 104-105, p. 47-52, 発行日 2022-01 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0969-8051 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nucmedbio.2021.11.006 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S0969805121005266 |