  1. 原著論文

Radiation robustness of laser ceramics and single crystal for microchip laser remote analysis

https://repo.qst.go.jp/records/84683
https://repo.qst.go.jp/records/84683
28879411-857c-464a-9270-71033a1b3044
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-12-06
タイトル
タイトル Radiation robustness of laser ceramics and single crystal for microchip laser remote analysis
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Koji, Tamura

× Koji, Tamura

WEKO 1042806

Koji, Tamura

Search repository
Ryuzo, Nakanishi

× Ryuzo, Nakanishi

WEKO 1042807

Ryuzo, Nakanishi

Search repository
Hironori, Oba

× Hironori, Oba

WEKO 1042808

Hironori, Oba

Search repository
Takunori, Taira

× Takunori, Taira

WEKO 1042809

Takunori, Taira

Search repository
Ikuo, Wakaida

× Ikuo, Wakaida

WEKO 1042810

Ikuo, Wakaida

Search repository
Koji, Tamura

× Koji, Tamura

WEKO 1042811

en Koji, Tamura

Search repository
Ryuzo, Nakanishi

× Ryuzo, Nakanishi

WEKO 1042812

en Ryuzo, Nakanishi

Search repository
Hironori, Oba

× Hironori, Oba

WEKO 1042813

en Hironori, Oba

Search repository
抄録
内容記述タイプ Abstract
内容記述 Laser pulse energy and pulse build-up time were measured during gamma irradiation at a dose rate of 150 Gy/h to evaluate the radiation-induced effects on a laser remote inspection system using ceramics and single crystal micro-chip laser. Results showed a time-dependent decrease in pulse energy and increase in pulse build-up time during irradiation. Both effects were larger for ceramics than for single crystal due to the amount of generated optical loss. The behaviours of pulse energy and build-up time with the increase in optical loss in the gain medium were simulated using rate equation calculations. The radiation effect on build-up time was larger than that on pulse energy for both specimens. Therefore, build-up time measurement is highly sensitive and effective for the evaluation of radiation effect generated in laser medium, especially for radiation robust specimens or at low radiation dose rate.
書誌情報 JJAP

巻 61, 号 3, p. 032003, 発行日 2022-04
出版者
出版者 応用物理学会物理系学術誌刊行センター
ISSN
収録物識別子タイプ ISSN
収録物識別子 0021-4922
DOI
識別子タイプ DOI
関連識別子 10.35848/1347-4065/ac4dd1
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.35848/1347-4065/ac4dd1
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:53:36.013813
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3