Space Radiation Dosimetry at the Exposure Facility of the International Space Station for the Tanpopo Mission

https://repo.qst.go.jp/records/84650
https://repo.qst.go.jp/records/84650
f59285f4-f155-4fb7-a822-f0ec466073ae
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-08-05
タイトル
タイトル Space Radiation Dosimetry at the Exposure Facility of the International Space Station for the Tanpopo Mission
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Satoshi, Kodaira

× Satoshi, Kodaira

WEKO 1070221

Satoshi, Kodaira

Search repository
Masayuki, Naito

× Masayuki, Naito

WEKO 1070222

Masayuki, Naito

Search repository
Yukio, Uchihori

× Yukio, Uchihori

WEKO 1070223

Yukio, Uchihori

Search repository
Hashimoto, Hirofumi

× Hashimoto, Hirofumi

WEKO 1070224

Hashimoto, Hirofumi

Search repository
Yano, Hajime

× Yano, Hajime

WEKO 1070225

Yano, Hajime

Search repository
Yamagishi, Akihiko

× Yamagishi, Akihiko

WEKO 1070226

Yamagishi, Akihiko

Search repository
Satoshi, Kodaira

× Satoshi, Kodaira

WEKO 1070227

en Satoshi, Kodaira

Search repository
Masayuki, Naito

× Masayuki, Naito

WEKO 1070228

en Masayuki, Naito

Search repository
Yukio, Uchihori

× Yukio, Uchihori

WEKO 1070229

en Yukio, Uchihori

Search repository
抄録
内容記述タイプ Abstract
内容記述 Radiation dosimetry was carried out at the exposure facility (EF) and the pressurized module (PM) of the Japanese Kibo module installed in the International Space Station as one study on environmental monitoring for the Tanpopo mission. Three exposure panels and three references including biological and organic samples and luminescence dosimeters were launched to obtain data for different exposure durations during 3 years from May 2015 to July 2018. The dosimeters were equipped with additional shielding materials (0.55, 2.95, and 6.23 g/cm2 mass thickness). The relative dose variation, as a function of shielding mass thickness, was observed and compared with Monte Carlo simulations with respect to galactic cosmic rays (GCRs) and typical solar energetic particles (SEPs). The mean annual dose rates were DEF = 231 ± 5 mGy/year at the EF and DPM = 82 ± 1 mGy/year at the PM during the 3 years. The PM is well shielded, and the GCR simulation indicated that the measured mean dose reduction ratio inside the module (DPM/DEF = 0.35) required ∼26 g/cm2 additional shielding mass thickness. Observed points of the dose reduction tendency could be explained by the energy ranges of protons (10–100 MeV), where the protons passed through, or were absorbed in, the shielding materials of different mass thickness that surrounded dosimeters.
書誌情報 Astrobiology

巻 21, 号 12, p. 1473-1478, 発行日 2021-12
出版者
出版者 Mary Ann Liebert, Inc., publishers
ISSN
収録物識別子タイプ ISSN
収録物識別子 1531-1074
DOI
識別子タイプ DOI
関連識別子 10.1089/ast.2020.2427
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1089/ast.2020.2427
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:44:29.738561
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3