ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Carbon Range Verification with 718 keV Compton Imaging

https://repo.qst.go.jp/records/84571
https://repo.qst.go.jp/records/84571
1db0647c-b5a5-482c-9e59-5d7a9762a5c7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-11-05
タイトル
タイトル Carbon Range Verification with 718 keV Compton Imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Parajuli, Raj

× Parajuli, Raj

WEKO 1020689

Parajuli, Raj

Search repository
Sakai, Makoto

× Sakai, Makoto

WEKO 1020690

Sakai, Makoto

Search repository
Arakawa, Kazuo

× Arakawa, Kazuo

WEKO 1020691

Arakawa, Kazuo

Search repository
Kubota, Yoshiki

× Kubota, Yoshiki

WEKO 1020692

Kubota, Yoshiki

Search repository
Kubo, Nobutero

× Kubo, Nobutero

WEKO 1020693

Kubo, Nobutero

Search repository
Tashiro, Matsumi

× Tashiro, Matsumi

WEKO 1020694

Tashiro, Matsumi

Search repository
Parajuli, Raj

× Parajuli, Raj

WEKO 1020695

en Parajuli, Raj

Search repository
抄録
内容記述タイプ Abstract
内容記述 Carbon ion radiotherapy is a sophisticated radiation treatment modality because of its superiority in achieving precise dosage distribution and high biological effectiveness. However, there exist beam range uncertainties that affect treatment efficiency. This problem can be resolved if the clinical beam could be monitored precisely in real-time, such as by imaging the prompt gamma emission from the target. In this study, we performed real-time detection and imaging of 718 keV prompt gamma emissions using a Si/CdTe Compton camera. We conducted experiments on graphite phantoms using clinical carbon ion beams of 290 MeV/u energy. Compton images were reconstructed using simple back-projection methods from the energy events of 718 keV prompt gamma emissions. The peak intensity position in reconstructed 718 keV prompt gamma images was few millimeters below the Bragg peak position. Moreover, the dual- and triple-energy window images for all positions of phantoms were not affected by scattered gammas, and their peak intensity positions were approximately similar to those observed in the reconstructed 718 keV prompt gamma images. In conclusion, the findings of the current study demonstrate the feasibility of using our Compton camera for real-time beam monitoring of carbon ion beams under clinical beam intensity.
書誌情報 Scientific Reports

巻 11, p. 21696, 発行日 2021-11
出版者
出版者 NATURE
ISSN
収録物識別子タイプ ISSN
収録物識別子 2045-2322
DOI
識別子タイプ DOI
関連識別子 10.1038/s41598-021-00949-5
関連サイト
識別子タイプ URI
関連識別子 https://www.nature.com/articles/s41598-021-00949-5#citeas
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:09:40.201912
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3