WEKO3
アイテム
1 MV Rectifier With SF6-Gas Insulation and Cooling for ITER Neutral Beam Injector System
https://repo.qst.go.jp/records/84562
https://repo.qst.go.jp/records/84562769fb1a4-37f8-4a60-a113-91818d4d193d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-11-17 | |||||
タイトル | ||||||
タイトル | 1 MV Rectifier With SF6-Gas Insulation and Cooling for ITER Neutral Beam Injector System | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Akeshi Takahashi
× Akeshi Takahashi× Suto, Tetsuya× Tanaka, Toshiaki× Yamaguchi, Kohei× Hiroyuki Fujita× Hiranuma, Yuki× Satoshi Ichimura× Kazuhiro, Watanabe× Mieko, Kashiwagi× Tetsuya, Maejima× Hiroyuki, Tobari× Kazuhiro, Watanabe× Mieko, Kashiwagi× Tetsuya, Maejima× Hiroyuki, Tobari |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This article presents the development results of a five-stage dc-1 MV rectifier for an international thermonuclear experimental reactor neutral beam injector system. Each rectifier outputs -200 kV, and the total five rectifiers are connected in a series. The feasibility of both gas insulation and gas cooling for semiconductor devices was validated to achieve dc-1 MV output and 1-h continuous operation. We devised a novel structure of cylindrical dense alignment of the heatsinks with stud-type diodes, which enables both the mitigation of electric-field concentration on the heatsinks and the improvement of heat dissipation from diodes. The difference in the temperature rise for three different directions of the heatsink in an SF 6 gas atmosphere was also clarified. The heat flow was analyzed to quantify the cooling effect of SF 6 gas, taking into account the gas circulation by the external cooling system. Rectification operation and temperature rise were tested with an actual-scale rectifier including a step-up transformer. Additionally, dc-1.2 MV withstand voltage was tested for a fifth-stage actual-scale rectifier. The test results demonstrated the validity of the proposed design. | |||||
書誌情報 |
IEEE Transactions on Industry Applications 巻 57, 号 5, p. 4398-4408, 発行日 2021-09 |
|||||
出版者 | ||||||
出版者 | IEEE | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0093-9994 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/TIA.2021.3096775 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://ieeexplore.ieee.org/document/9484737 |