ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

High-energy per-pixel calibration of timepix pixel detector with laboratory alpha source

https://repo.qst.go.jp/records/84556
https://repo.qst.go.jp/records/84556
bfda2a5a-6dd5-4203-9967-c0ff055e4baa
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-11-19
タイトル
タイトル High-energy per-pixel calibration of timepix pixel detector with laboratory alpha source
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sommer, Marek

× Sommer, Marek

WEKO 1070242

Sommer, Marek

Search repository
Granja, Carlos

× Granja, Carlos

WEKO 1070243

Granja, Carlos

Search repository
Satoshi, Kodaira

× Satoshi, Kodaira

WEKO 1070244

Satoshi, Kodaira

Search repository
Ploc, Ondrej

× Ploc, Ondrej

WEKO 1070245

Ploc, Ondrej

Search repository
Satoshi, Kodaira

× Satoshi, Kodaira

WEKO 1070246

en Satoshi, Kodaira

Search repository
抄録
内容記述タイプ Abstract
内容記述 The spectral response of the pixel detector Timepix at the high per-pixel proportional range is examined and calibrated using a simple technique and alpha particles from a standard laboratory source in air. For the detector used, a Timepix ASIC chip equipped with a 300 μ m thick silicon sensor, the spectral range is newly extended up to about 1750 keV per-pixel. This expands and covers the region above 850 keV per pixel which is described and covered by the existing low-energy calibration. The low-energy calibration uses discrete low-energy gamma rays in the range 5–60 keV and is extrapolated over the linear range up to 850 keV/px. Above this level, the per-pixel spectral response changes. At higher energies it undergoes distortion and saturation. The proportional and monotonic response is observed with regions of varying dependence up to nearly 2 MeV. This high-energy region is covered and described by the newly developed calibration method which Uses an alpha source of common low activity (kBq level). Data are collected within one day of total measuring time. Measurements are performed in air at various source-to-distance positions and several sensor bias settings. The developed method together with suitable setting of the sensor bias, which determines the extent of charge sharing, expands the spectral response of Timepix to high energy-loss particles such as alpha particles and light ions in wide energy range. Results are demonstrated on alpha particles, protons and12C ions. Resulting spectra of deposited energy and cluster pixel height are correctly calibrated and they reproduce expected values.
書誌情報 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

巻 1022, p. 165957, 発行日 2022-01
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2021.165957
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.nima.2021.165957
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:44:28.132638
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3