WEKO3
アイテム
High-energy per-pixel calibration of timepix pixel detector with laboratory alpha source
https://repo.qst.go.jp/records/84556
https://repo.qst.go.jp/records/84556bfda2a5a-6dd5-4203-9967-c0ff055e4baa
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-11-19 | |||||
タイトル | ||||||
タイトル | High-energy per-pixel calibration of timepix pixel detector with laboratory alpha source | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Sommer, Marek
× Sommer, Marek× Granja, Carlos× Satoshi, Kodaira× Ploc, Ondrej× Satoshi, Kodaira |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The spectral response of the pixel detector Timepix at the high per-pixel proportional range is examined and calibrated using a simple technique and alpha particles from a standard laboratory source in air. For the detector used, a Timepix ASIC chip equipped with a 300 μ m thick silicon sensor, the spectral range is newly extended up to about 1750 keV per-pixel. This expands and covers the region above 850 keV per pixel which is described and covered by the existing low-energy calibration. The low-energy calibration uses discrete low-energy gamma rays in the range 5–60 keV and is extrapolated over the linear range up to 850 keV/px. Above this level, the per-pixel spectral response changes. At higher energies it undergoes distortion and saturation. The proportional and monotonic response is observed with regions of varying dependence up to nearly 2 MeV. This high-energy region is covered and described by the newly developed calibration method which Uses an alpha source of common low activity (kBq level). Data are collected within one day of total measuring time. Measurements are performed in air at various source-to-distance positions and several sensor bias settings. The developed method together with suitable setting of the sensor bias, which determines the extent of charge sharing, expands the spectral response of Timepix to high energy-loss particles such as alpha particles and light ions in wide energy range. Results are demonstrated on alpha particles, protons and12C ions. Resulting spectra of deposited energy and cluster pixel height are correctly calibrated and they reproduce expected values. | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 巻 1022, p. 165957, 発行日 2022-01 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0168-9002 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nima.2021.165957 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.nima.2021.165957 |