WEKO3
アイテム
Strategy to Reduce the Collective Equivalent Dose for the Lens of the Physician’s Eye Using Short Radiation Protection Curtains to Prevent Cataracts
https://repo.qst.go.jp/records/84425
https://repo.qst.go.jp/records/844252d1fd103-cab9-426c-ac4c-71f996a47bfb
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-10-14 | |||||
タイトル | ||||||
タイトル | Strategy to Reduce the Collective Equivalent Dose for the Lens of the Physician’s Eye Using Short Radiation Protection Curtains to Prevent Cataracts | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nakagami, Koichi
× Nakagami, Koichi× Moritake, Takashi× Nagamoto, Keisuke× Morota, Koichi× Matsuzaki, Satoru× Kuriyama, Tomoko× Kunugita, Naoki× Takashi, Moritake× Naoki, Kunugita |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A short curtain that improves on the low versatility of existing long curtains was developed as a dedicated radiation protective device for the over-table tube fluorographic imaging units. The effect of this short curtain in preventing cataracts was then examined. First, the physician lens dose reduction rate was obtained at the position of the lens. Next, the reduction rate in the collective equivalent dose for the lens of the physician's eye was estimated. The results showed that lens dose reduction rates with the long curtain and the short curtain were 88.9% (literature-based value) and 17.6%, respectively, higher with the long curtain. In our hospital, the reduction rate in the collective equivalent dose for the lens of the physician's eye was 9.8% and 17.6% with a procedures mixture, using the long curtain where technically possible and no curtain in all other procedures, and the short curtain in all procedures, respectively, higher with the short curtain. Moreover, a best available for curtains raised the reduction rate in the collective equivalent dose for the lens of the physician's eye a maximum of 25.5%. By introducing the short curtain, it can be expected to have an effect in preventing cataracts in medical staff. | |||||
書誌情報 |
Diagnostics 巻 11, 号 8, p. 1415, 発行日 2021-08 |
|||||
出版者 | ||||||
出版者 | MDPI | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2075-4418 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 34441349 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.3390/diagnostics11081415 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.mdpi.com/2075-4418/11/8/1415 |