Development of a new analytic method for miter bend polarizer on ECW transmission line

https://repo.qst.go.jp/records/84240
https://repo.qst.go.jp/records/84240
2facf361-a87c-4854-892d-9558d383e745
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-03-10
タイトル
タイトル Development of a new analytic method for miter bend polarizer on ECW transmission line
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Satoru, Yajima

× Satoru, Yajima

WEKO 1017611

Satoru, Yajima

Search repository
Takayuki, Kobayashi

× Takayuki, Kobayashi

WEKO 1017612

Takayuki, Kobayashi

Search repository
Ken, Kajiwara

× Ken, Kajiwara

WEKO 1017613

Ken, Kajiwara

Search repository
Ryosuke, Ikeda

× Ryosuke, Ikeda

WEKO 1017614

Ryosuke, Ikeda

Search repository
Koji, Takahashi

× Koji, Takahashi

WEKO 1017615

Koji, Takahashi

Search repository
Satoru, Yajima

× Satoru, Yajima

WEKO 1017616

en Satoru, Yajima

Search repository
Takayuki, Kobayashi

× Takayuki, Kobayashi

WEKO 1017617

en Takayuki, Kobayashi

Search repository
Ken, Kajiwara

× Ken, Kajiwara

WEKO 1017618

en Ken, Kajiwara

Search repository
Ryosuke, Ikeda

× Ryosuke, Ikeda

WEKO 1017619

en Ryosuke, Ikeda

Search repository
Koji, Takahashi

× Koji, Takahashi

WEKO 1017620

en Koji, Takahashi

Search repository
抄録
内容記述タイプ Abstract
内容記述 For successful tokamak operation with adequate mode selection of the electron cyclotron wave, launching wave polarization should be accurately controlled. In this study, a new method is proposed to efficiently identify the response of polarizers using a geometric approach in the Stokes space, focusing on the fact that polarization can be represented as a vector in Stokes space and the response of a polarizer can be described as a rotation. The proposed methods are intended (i) to determine the response parameters of a polarizer or (ii) to determine the response parameters of two polarizers simultaneously. A simple measurement system was prepared to observe the polarizers’ output polarization in the 110/138 GHz transmission line. The determined response parameters of two polarizers can reproduce measured polarizations with sufficient accuracy above 99 %. The direction of an output polarization circularity, the only feature of a polarization that could not be directly known from the prepared measurement, could also be determined with sufficient accuracy.
書誌情報 Fusion Engineering and Design

巻 171, p. 112487, 発行日 2021-09
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0920-3796
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2021.112487
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S0920379621002635?via%3Dihub
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:13:15.728042
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3