Dose response of a radiophotoluminescent glass dosimeter for TomoTherapy, CyberKnife, and flattening-filter-free linear accelerator output measurements in dosimetry audit
https://repo.qst.go.jp/records/84055
https://repo.qst.go.jp/records/8405521480516-673a-4ea2-b4e2-1795babefdf4
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-07-29 | |||||
タイトル | ||||||
タイトル | Dose response of a radiophotoluminescent glass dosimeter for TomoTherapy, CyberKnife, and flattening-filter-free linear accelerator output measurements in dosimetry audit | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hideyuki, Mizuno
× Hideyuki, Mizuno× Yamashita, Wataru× Okuyama, Hiroaki× Takase, Nobuhiro× Tohyama, Naoki× Shimizu, Hidetoshi× Fujita, Yukio× Kito, Satoshi× Taku, Nakaji× Shigekazu, Fukuda× Hideyuki, Mizuno× Taku, Nakaji× Shigekazu, Fukuda |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: We experimentally determined the radiophotoluminescent glass dosimeter (RPLD) dose responses for TomoTherapy, CyberKnife, and flattening-filter-free (FFF) linear accelerator (linac) outputs for dosimetry audits in Japan. Methods: A custom-made solid phantom with a narrow central-axis spacing of three RPLD elements was used for output measurement to minimise the dose-gradient effect of the non-flattening filter beams. For RPLD dose estimation, we used the ISO 22127 formalism. Additional unit-specific correction factors were introduced and determined via the measured data. For TomoTherapy (7 units) and CyberKnife (4 units), the doses were measured under machine-specific reference fields. For FFF linac (5 units), in addition to the reference condition, we obtained the field-size effects for the range from 5 × 5 cm to 25 × 25 cm. Results: The correction factors were estimated as 1.008 and 0.999 for TomoTherapy and CyberKnife, respectively. For FFF linac, they ranged from 1.011 to 0.988 for 6 MV and from 1.011 to 0.997 for 10 MV as a function of the side length of the square field from 5 to 25 cm. The estimated uncertainties of the absorbed dose to water measured by RPLD for the units were 1.32%, 1.35%, and 1.30% for TomoTherapy, CyberKnife, and FFF linac, respectively. A summary of the dosimetry audits of these treatment units using the obtained correction factors is also presented. The average percentage differences between the measured and hospital-stated doses were <1% under all conditions. Conclusion: RPLD can be successfully used as a dosimetry audit tool for modern treatment units. |
|||||
書誌情報 |
Physica Medica 巻 88, p. 91-97, 発行日 2021-08 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1120-1797 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 34214838 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.ejmp.2021.06.010 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/pii/S1120179721002301?via%3Dihub |