WEKO3
アイテム
Primary electron analysis to improve the negative ion uniformity toward ITER-class long pulse and high-power negative ion sources
https://repo.qst.go.jp/records/84023
https://repo.qst.go.jp/records/8402313295def-4e0e-4355-8113-c9ec694dab7d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-08-19 | |||||
タイトル | ||||||
タイトル | Primary electron analysis to improve the negative ion uniformity toward ITER-class long pulse and high-power negative ion sources | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yuji, Shimabukuro
× Yuji, Shimabukuro× Masahiro, Ichikawa× Masamichi, Murayama× mae quinones Saquilayan, Glynnis× Atsushi, Kojima× Hiroyuki, Tobari× Mieko, Kashiwagi× Yuji, Shimabukuro× Masahiro, Ichikawa× Masamichi, Murayama× mae quinones Saquilayan, Glynnis× Atsushi, Kojima× Hiroyuki, Tobari× Mieko, Kashiwagi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A novel Eclair-shaped filter magnetic field with no primary electron leakage has been proposed to reduce the co-extracted electrons and improve the spatial uniformity of negative ion production. A primary electron analysis was conducted to clarify its spatial distribution and the issue of current magnetic field configuration because the experimental data imply that the negative ion population is low on the edge segments due to the many primary electrons around there. A simulation study revealed that the low capability of electron confinement at the KAMABOKO source's edge region due to the localized magnetically weak points induces the primary electron leakage, which causes high co-extracted electron current and negative ion non-uniformity. Calculation results showed a new design index that contributes to the complete suppression of primary electron leakage to the extraction region with a permanent magnet connection angle of 108 degrees or more. The Eclair-shaped ion source has been designed based upon the obtained index about the connection angle to realize the ideal magnetic configuration without primary electron leakage to the extraction region. |
|||||
書誌情報 |
AIP Conference Proceedings 巻 2373, 号 1, p. 030005-1-030005-10, 発行日 2021-07 |
|||||
出版者 | ||||||
出版者 | AIP Publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0094-243X | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/5.0057507 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://aip.scitation.org/doi/abs/10.1063/5.0057507 |