Proton-Cluster-Beam Lethality and Mutagenicity in Bacillus subtilis Spores

https://repo.qst.go.jp/records/84020
https://repo.qst.go.jp/records/84020
6906be2e-def7-42bf-b8bb-62947cb6b436
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-04-16
タイトル
タイトル Proton-Cluster-Beam Lethality and Mutagenicity in Bacillus subtilis Spores
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshihiro, Hase

× Yoshihiro, Hase

WEKO 1014827

Yoshihiro, Hase

Search repository
Katsuya, Sato

× Katsuya, Sato

WEKO 1014828

Katsuya, Sato

Search repository
Atsuya, Chiba

× Atsuya, Chiba

WEKO 1014829

Atsuya, Chiba

Search repository
Yoshimi, Hirano

× Yoshimi, Hirano

WEKO 1014830

Yoshimi, Hirano

Search repository
Kengo, Moribayashi

× Kengo, Moribayashi

WEKO 1014831

Kengo, Moribayashi

Search repository
Kazumasa, Narumi

× Kazumasa, Narumi

WEKO 1014832

Kazumasa, Narumi

Search repository
Yoshihiro, Hase

× Yoshihiro, Hase

WEKO 1014833

en Yoshihiro, Hase

Search repository
Katsuya, Sato

× Katsuya, Sato

WEKO 1014834

en Katsuya, Sato

Search repository
Atsuya, Chiba

× Atsuya, Chiba

WEKO 1014835

en Atsuya, Chiba

Search repository
Yoshimi, Hirano

× Yoshimi, Hirano

WEKO 1014836

en Yoshimi, Hirano

Search repository
Kengo, Moribayashi

× Kengo, Moribayashi

WEKO 1014837

en Kengo, Moribayashi

Search repository
Kazumasa, Narumi

× Kazumasa, Narumi

WEKO 1014838

en Kazumasa, Narumi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The unique energy transfer characteristics of swift cluster ions have attracted the attention of many researchers working on the analysis or processing of material surfaces, but the effects on living organisms remain unclear. We irradiated B. subtilis spores with monomer and cluster proton beams and examined their lethality; the 2-MeV H2+ shows a clearly lower lethality than 340-keV H+, even though both have a comparable linear energy transfer. The 2-MeV H2+ dissoci-ates into a pair of 1-MeV H+ by losing the bonding electrons at the target surface. The estimated internuclear distance and the radial dose distribution suggest that the spread of deposited total energy over two areas separated by just several nanometers greatly diminishes beam lethality, and that the energy density in the very center of the trajectory, possibly within a 1-nm radius, has a great impact on lethality. We also performed a whole genome resequencing of the surviv-ing colonies to compare the molecular nature of mutations but failed to find a clear difference in overall characteristics. Our results suggest that cluster beams may be a useful tool for under-standing biological effects of high linear energy transfer radiation.
書誌情報 Quantum Beam Science

巻 5, 号 3, p. 25, 発行日 2021-08
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 2412-382X
DOI
識別子タイプ DOI
関連識別子 10.3390/qubs5030025
関連サイト
識別子タイプ URI
関連識別子 https://www.mdpi.com/2412-382X/5/3/25
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:16:28.731257
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3