WEKO3
アイテム
First experimental results of gated proton imaging using x-ray fluoroscopy to detect a fiducial marker
https://repo.qst.go.jp/records/83848
https://repo.qst.go.jp/records/83848d3fdf9cb-b042-4dd3-8e78-53f861763eed
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-08-31 | |||||
タイトル | ||||||
タイトル | First experimental results of gated proton imaging using x-ray fluoroscopy to detect a fiducial marker | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tanaka, Sodai
× Tanaka, Sodai× Miyamoto, Naoki× Matsuo, Yuto× Yoshimura, Takaaki× Takao, Seishin× Matsuura, Taeko× Sodai, Tanaka |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Increasing numbers of proton imaging research studies are being conducted for accurate proton range determination in proton therapy treatment planning. However, there is no proton imaging system that deals with motion artifacts. In this study, a gated proton imaging system was developed and the first experimental results of proton radiography were obtained for a moving object without motion artifacts. A motion management system using dual x-ray fluoroscopy for detecting a spherical gold fiducial marker was introduced and the proton beam was gated in accordance with the motion of the object. To demonstrate the performance of the gated proton imaging system, gated proton radiography images of a moving phantom were acquired experimentally, and the motion artifacts clearly were diminished. Also, the factors causing image deteriorations were evaluated focusing on the new gating system developed here, and the main factor was identified as the latency (with a maximum value of 93 ms) between the ideal gating signal according to the actual marker position and the actual gating signal. The possible deterioration due to the latency of the proton imaging system and proton beam irradiation was small owing to appropriate setting of the time structure. | |||||
書誌情報 |
Physics in medicine and biology 巻 66, 号 18, p. 18NT03, 発行日 2021-08 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-9155 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 34433146 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/1361-6560/ac212b | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://iopscience.iop.org/article/10.1088/1361-6560/ac212b |