First experimental results of gated proton imaging using x-ray fluoroscopy to detect a fiducial marker

https://repo.qst.go.jp/records/83848
https://repo.qst.go.jp/records/83848
d3fdf9cb-b042-4dd3-8e78-53f861763eed
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-08-31
タイトル
タイトル First experimental results of gated proton imaging using x-ray fluoroscopy to detect a fiducial marker
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tanaka, Sodai

× Tanaka, Sodai

WEKO 1064658

Tanaka, Sodai

Search repository
Miyamoto, Naoki

× Miyamoto, Naoki

WEKO 1064659

Miyamoto, Naoki

Search repository
Matsuo, Yuto

× Matsuo, Yuto

WEKO 1064660

Matsuo, Yuto

Search repository
Yoshimura, Takaaki

× Yoshimura, Takaaki

WEKO 1064661

Yoshimura, Takaaki

Search repository
Takao, Seishin

× Takao, Seishin

WEKO 1064662

Takao, Seishin

Search repository
Matsuura, Taeko

× Matsuura, Taeko

WEKO 1064663

Matsuura, Taeko

Search repository
Sodai, Tanaka

× Sodai, Tanaka

WEKO 1064664

en Sodai, Tanaka

Search repository
抄録
内容記述タイプ Abstract
内容記述 Increasing numbers of proton imaging research studies are being conducted for accurate proton range determination in proton therapy treatment planning. However, there is no proton imaging system that deals with motion artifacts. In this study, a gated proton imaging system was developed and the first experimental results of proton radiography were obtained for a moving object without motion artifacts. A motion management system using dual x-ray fluoroscopy for detecting a spherical gold fiducial marker was introduced and the proton beam was gated in accordance with the motion of the object. To demonstrate the performance of the gated proton imaging system, gated proton radiography images of a moving phantom were acquired experimentally, and the motion artifacts clearly were diminished. Also, the factors causing image deteriorations were evaluated focusing on the new gating system developed here, and the main factor was identified as the latency (with a maximum value of 93 ms) between the ideal gating signal according to the actual marker position and the actual gating signal. The possible deterioration due to the latency of the proton imaging system and proton beam irradiation was small owing to appropriate setting of the time structure.
書誌情報 Physics in medicine and biology

巻 66, 号 18, p. 18NT03, 発行日 2021-08
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
PubMed番号
識別子タイプ PMID
関連識別子 34433146
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/ac212b
関連サイト
識別子タイプ URI
関連識別子 https://iopscience.iop.org/article/10.1088/1361-6560/ac212b
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 16:44:41.340626
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3