Gapless implementation of crosshair light-sharing PET detector

https://repo.qst.go.jp/records/83786
https://repo.qst.go.jp/records/83786
84275b86-8d4e-4de9-9354-4e4ab53463cd
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-11-05
タイトル
タイトル Gapless implementation of crosshair light-sharing PET detector
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Eiji, Yoshida

× Eiji, Yoshida

WEKO 1010387

Eiji, Yoshida

Search repository
Fujino, Obata

× Fujino, Obata

WEKO 1010388

Fujino, Obata

Search repository
Kamada, Kei

× Kamada, Kei

WEKO 1010389

Kamada, Kei

Search repository
Yoshikawa, Akira

× Yoshikawa, Akira

WEKO 1010390

Yoshikawa, Akira

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1010391

Taiga, Yamaya

Search repository
Eiji, Yoshida

× Eiji, Yoshida

WEKO 1010392

en Eiji, Yoshida

Search repository
Fujino, Obata

× Fujino, Obata

WEKO 1010393

en Fujino, Obata

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1010394

en Taiga, Yamaya

Search repository
抄録
内容記述タイプ Abstract
内容記述 Recently, silicon photomultipliers (SiPMs) have become established as photo-sensors for PET scanners. Commercially available SiPM arrays are typically about 3–4 cm in size. In order to develop larger detectors with an Anger calculation, multiple SiPM arrays need to be combined. This configuration requires the use of a light guide and has inactive areas between SiPM arrays. If not addressed, crystal identification degrades not only for peripheral crystals but also for crystals to bridge the gap between the SiPM arrays. On the other hand, we have developed the crosshair light-sharing (CLS) PET detector, which is based on a single-ended readout scheme with roughly quadrisected crystals comparable in size to a SiPM, with depth-of-interaction (DOI) capability. The CLS PET detector based on the local centroid calculation was expected to mitigate the edge effect similar to what the one-to-one coupling detector is able to do. In this work, we developed the axially long CLS PET detector with two multipixel photon counter (MPPC) arrays. The proposed long CLS PET detector consisted of 30 × 14 gadolinium fine aluminum garnet (GFAG) arrays coupled to two 8 × 8 MPPC arrays without the light guide. From 511-keV uniform irradiation, responses of all crystal elements could be separated clearly on a 2D position histogram after applying the Anger calculation. Pulse heights of additional crystals to bridge the gap were 18% lower than those of crystals at the center of the MPPC array, but similar to that of the peripheral crystals based on non-uniformity of the MPPC array. On the other hand, energy resolutions of additional crystals to bridge the gap were almost the same to those of other crystals. The long CLS PET detector promises improvement of the packing fraction while keeping performance.
書誌情報 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

巻 1021, p. 165922, 発行日 2022-01
出版者
出版者 Elsevier B.V.
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2021.165922
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S0168900221008901?dgcid=coauthor
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:21:24.116753
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3