Accurate measurement of 90Sr at Ultra trace levels in Environmental Samples using Thermal Ionization Mass Spectrometry

https://repo.qst.go.jp/records/83709
https://repo.qst.go.jp/records/83709
781edd9c-a509-499f-801f-9b15d020108d
Item type 会議発表用資料 / Presentation(1)
公開日 2021-10-29
タイトル
タイトル Accurate measurement of 90Sr at Ultra trace levels in Environmental Samples using Thermal Ionization Mass Spectrometry
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sarata Kumar, SAHOO

× Sarata Kumar, SAHOO

WEKO 1009176

Sarata Kumar, SAHOO

Search repository
Norbert , KAVASI

× Norbert , KAVASI

WEKO 1009177

Norbert , KAVASI

Search repository
Tatsuo, AONO

× Tatsuo, AONO

WEKO 1009178

Tatsuo, AONO

Search repository
Sahoo, Sarata

× Sahoo, Sarata

WEKO 1009179

en Sahoo, Sarata

Search repository
Kavasi, Norbert

× Kavasi, Norbert

WEKO 1009180

en Kavasi, Norbert

Search repository
Tatsuo, Aono

× Tatsuo, Aono

WEKO 1009181

en Tatsuo, Aono

Search repository
抄録
内容記述タイプ Abstract
内容記述 The 90Sr (T1/2 = 28.8 y) is a pure beta emitter radioisotope, produced by the fission of U and Pu isotopes. Low level (some Bq/kg or mBq/kg) 90Sr contamination exists in different environmental matrices as a result of nuclear weapon tests and nuclear accidents. The Sr element shows bio-chemically similarity to calcium, therefore the 90Sr isotope can incorporate into the human bone structure causing long-term radiation dose.
Considering the public health and natural radiation protection, precise and accurate determination of 90Sr in various environmental, biological and radioactive waste samples is important.
Radiometric methods have been mainly used for 90Sr analysis. However, significant developments on sample introduction, detector and interference removal techniques, many successful 90Sr determinations have been reported using mass spectrometry instruments. The main advantages of the mass spectrometry method over the radiometric are the shorter analysis time, higher sample throughput and smaller sample intake.
In this work, a new 90Sr analysis method using Thermal Ionization Mass Spectrometry (TIMS) equipped with a Daly ion-counting system will be introduced. Detection of 0.2 fg (1 mBq) 90Sr was demonstrated with an excellent abundance sensitivity for the 90Sr/88Sr isotope ratio (2.1×10e-10). For method validation, certified reference material (wild berry-IRMM-426, 90Sr= 124±24 Bq/ /kg) and standard reference material (freshwater lake sediment-NIST-4354, 90Sr= 512±118 Bq/kg) were analysed.
This new method was applied for the first time in the history of mass-spectrometry in a worldwide open proficiency test (IAEA-TEL 2017-3). The 90Sr was determined in tap water and milk powder samples and values were ‘accepted’ with both accuracy and precision.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Fukushima 10 years: Forest, River, Ocean, and Food
発表年月日
日付 2021-10-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:22:48.008170
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3