WEKO3
アイテム
Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure
https://repo.qst.go.jp/records/83448
https://repo.qst.go.jp/records/834483fe2cd8c-122c-4ac9-b63e-6406db6f2bcb
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-08-25 | |||||
タイトル | ||||||
タイトル | Effects of Storage Time and Pre-Etching Treatment of CR-39 Detectors on Their Response to Alpha Radiation Exposure | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Janik, Miroslaw
× Janik, Miroslaw× Mahamudul Hasan, MD× Bossew, Peter× Kavasi, Norbert× Janik, Miroslaw× Mahamudul Hasan, MD× Kavasi, Norbert |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Radon passive monitors based on solid state nuclear track detectors (SSNTD), especially CR-39, are widely used in radon and thoron studies. They may be subjected to the influence of external factors, like changing of temperature, humidity, and pressure, both before and during the measurement. Evaluation of the exposed detectors involves chemical processing, whose conditions also influence the measurement results. The aim of this study was to check several factors, as to whether they may modify the response of CR-39 detector: concerning the phase before evaluation, storage time, and temperature during storage; and concerning the evaluation procedure, etching time, and pre-etching treatment using hot water and carbon dioxide atmosphere. Two experiments were conducted by irradiation of CR-39 detectors using alpha particles emitted from a mono-energetic 241Am source and exposed in radon atmosphere. Track density dependence of the age of production was found to be statistically not significant. On the other hand, pre-etching treatment using hot water and carbon dioxide with different etching times showed statistically significant effects on track area, track sensitivity, and roundness. It was concluded that there are simple methods to increase performance of nuclear track detectors, and that storage time is not a factor of concern. | |||||
書誌情報 |
International Journal of Environmental Research and Public Health 巻 18, 号 16, p. 8346, 発行日 2021-08 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1660-4601 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.3390/ijerph18168346 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.mdpi.com/1660-4601/18/16/8346 |