アイテム

  1. 学会発表・講演等
  2. ポスター発表

First prototype of a novel dual round-edge detector arrangement for breast PET imaging

https://repo.qst.go.jp/records/83033
https://repo.qst.go.jp/records/83033
6c809e58-f899-4857-bdfd-957ef15117ac
Item type 会議発表用資料 / Presentation(1)
公開日 2021-06-25
タイトル
タイトル First prototype of a novel dual round-edge detector arrangement for breast PET imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Go, Akamatsu

× Go, Akamatsu

WEKO 995239

Go, Akamatsu

Search repository
Eiji, Yoshida

× Eiji, Yoshida

WEKO 995240

Eiji, Yoshida

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 995241

Hideaki, Tashima

Search repository
Shigeki, Ito

× Shigeki, Ito

WEKO 995242

Shigeki, Ito

Search repository
Miwako, Takahashi

× Miwako, Takahashi

WEKO 995243

Miwako, Takahashi

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 995244

Taiga, Yamaya

Search repository
Go, Akamatsu

× Go, Akamatsu

WEKO 995245

en Go, Akamatsu

Search repository
Eiji, Yoshida

× Eiji, Yoshida

WEKO 995246

en Eiji, Yoshida

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 995247

en Hideaki, Tashima

Search repository
Shigeki, Ito

× Shigeki, Ito

WEKO 995248

en Shigeki, Ito

Search repository
Miwako, Takahashi

× Miwako, Takahashi

WEKO 995249

en Miwako, Takahashi

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 995250

en Taiga, Yamaya

Search repository
抄録
内容記述タイプ Abstract
内容記述 [Objectives] 18F-FDG PET is useful for diagnosis of breast cancer. Compared to whole-body imaging, local breast imaging with a dedicated PET system can more clearly visualize the extent of the primary breast tumor and axillary lymph nodes metastasis. Breast-dedicated PET systems are categorized into two geometries: a ring-shaped detector arrangement and a dual flat-panel detector arrangement. Although the flat-panel system allows imaging axillary lymph nodes from a similar view as X-ray mammography, PET images are blurred (i.e. spatial resolution is degraded) in the direction perpendicular to the detectors due to the limited angular coverage. To compensate for this issue, we proposed a dual round-edge detector arrangement, in which the detector blocks at both edge positions were tilted toward the center of the field-of-view (FOV). The proposed detector arrangement is expected to reduce image blurring and improve spatial resolution while keeping the advantages of the dual panel arrangement. For a proof of concept, we developed a small prototype and evaluated the spatial resolution.
[Methods] We used the crosshair light-sharing (CLS) detectors which had depth-of-interaction (DOI) and time-of-flight (TOF) measurement capabilities*. A 14×14 array of 1.45×1.45×15 mm3 GFAG scintillator was coupled with an 8×8 array of silicon photomultipliers (SiPMs) each with a photosensitive area of 3.0×3.0 mm2. DOI was digitalized into three bins. The data acquisition system was the TOFPET2 ASIC (PETsys Electronics), which was designed to digitize energy and time signals from photo sensors. The small prototype was composed of 32 detector blocks. We examined the conventional flat-panel arrangement and our proposed round-edge arrangement. A 22Na Derenzo-like multi-rod phantom (rod diameters: 1.6, 2.2, 3.0, 4.0, 5.0 and 6.0 mm) was used for spatial resolution measurement. The phantom was measured (90 min) in the two directions (coronal and axial planes) at the center of the FOV.
[Results] In the coronal plane, the 1.6 mm rods were clearly resolved in both arrangements. In the axial plane, the round-edge arrangement significantly improved the spatial resolution compared with the flat-panel arrangement. While the conventional flat-panel arrangement could not resolve the 3.0 mm rods, the proposed round-edge arrangement resolved the 2.2 mm rods.
[Conclusion] The proposed dual round-edge detector arrangement showed better spatial resolution than the conventional flat-panel arrangement while keeping the geometrical advantage for the breast PET imaging.
(*Yoshida, et al. A crosshair light sharing PET detector with DOI and TOF capabilities using four-to-one coupling and single-ended readout. IEEE TRPMS 2020.)
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 SNMMI 2021 Annual Meeting
発表年月日
日付 2021-06-11
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:37:21.808894
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3