Improved accuracy of amyloid PET quantification with adaptive template-based anatomic standardization

https://repo.qst.go.jp/records/82942
https://repo.qst.go.jp/records/82942
d73af6f3-1a7d-4a14-9dc7-e28344e69b48
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-06-04
タイトル
タイトル Improved accuracy of amyloid PET quantification with adaptive template-based anatomic standardization
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yuma, Tsubaki

× Yuma, Tsubaki

WEKO 1014911

Yuma, Tsubaki

Search repository
Takayoshi, Kitamura

× Takayoshi, Kitamura

WEKO 1014912

Takayoshi, Kitamura

Search repository
Natsumi, Shimokawa

× Natsumi, Shimokawa

WEKO 1014913

Natsumi, Shimokawa

Search repository
Go, Akamatsu

× Go, Akamatsu

WEKO 1014914

Go, Akamatsu

Search repository
Masayuki, Sasaki

× Masayuki, Sasaki

WEKO 1014915

Masayuki, Sasaki

Search repository
Go, Akamatsu

× Go, Akamatsu

WEKO 1014916

en Go, Akamatsu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Amyloid positron emission tomography (PET) noninvasively visualizes amyloid-β (Aβ) accumulation in the brain. Visual binary reading is the standard method for interpreting amyloid PET, while objective quantitative evaluation is required in research and clinical trials. Anatomical standardization is important for quantitative analysis, and various standard templates are used for this purpose. To address the large differences in the radioactivity distribution between amyloid-positive and amyloid-negative participants, an adaptive template method has been proposed for the anatomical standardization of amyloid PET. In this study, we investigated the difference between the adaptive template method and the single template methods (use of a positive or a negative template) in amyloid PET quantitative evaluation, focusing on the accuracy in diagnosing Alzheimer's disease (AD). A total of 166 participants (58 normal controls (NCs), 62 participants with mild cognitive impairment (MCI), and 46 patients with AD) who underwent [C] Pittsburgh Compound B PET (C-PiB) through the Japanese Alzheimer's Disease Neuroimaging Initiative study were examined. For the anatomical standardization of C-PiB PET images, we applied three methods a positive template-based method, a negative template-based method, and adaptive template-based method. The positive template was created by averaged four patients with AD and seven patients with MCI PET images. Conversely, the negative template was created by averaged eight participants of NC PET images. In the adaptive template-based method, either of the templates was used on the basis of the similarity (normalized cross-correlation (NCC)) between the individual standardized image and the corresponding template. Empirical PiB-prone region-of-interest was used to evaluate specific regions where Aβ accumulates. The reference region was the cerebellar cortex, whereas the evaluated regions were the posterior cingulate gyrus and precuneus as well as the frontal, lateral temporal, lateral parietal, and occipital lobes. The mean cortical standardized uptake value ratio (mcSUVR) was calculated for quantitative evaluation. The NCCs of single template-based methods (the positive template or negative template) showed a significant difference between NC, MCI and AD ( < 0.05), whereas the NCC of the adaptive template-based method did not ( > 0.05). The mcSUVR exhibited significant differences between NC, MCI and AD in all methods ( < 0.05). The area under curve by receiver operating characteristic analysis between the positive group (MCI and AD) and NC was not significantly different in mcSUVR among all templates. With regard to diagnostic accuracy based on mcSUVR, the sensitivity of the negative and adaptive template-based methods was superior to that of the positive template-based method ( < 0.05); however, there was no significant difference in specificity between them. In the diagnostic accuracy for AD by amyloid PET quantitative evaluation, the adaptive template-based anatomical standardization method outperformed the single template-based methods.
書誌情報 Journal of nuclear medicine technology

巻 49, 号 3, p. 256-261, 発行日 2021-01
出版者
出版者 Society of Nuclear Medicine and Molecular Imaging
ISSN
収録物識別子タイプ ISSN
収録物識別子 0091-4916
PubMed番号
識別子タイプ PMID
関連識別子 33820861
DOI
識別子タイプ DOI
関連識別子 10.2967/jnmt.120.261701
関連サイト
識別子タイプ URI
関連識別子 https://tech.snmjournals.org/content/49/3/256
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:16:19.249115
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3