Expanded two-color thermography considering temperature-dependent emissivity of tungsten for ITER divertor infrared thermography

https://repo.qst.go.jp/records/82926
https://repo.qst.go.jp/records/82926
a70c7a7a-9f71-4bd7-8656-83781dc24339
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-06-04
タイトル
タイトル Expanded two-color thermography considering temperature-dependent emissivity of tungsten for ITER divertor infrared thermography
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tomohiko, Ushiki

× Tomohiko, Ushiki

WEKO 996646

Tomohiko, Ushiki

Search repository
Ryota, Imazawa

× Ryota, Imazawa

WEKO 996647

Ryota, Imazawa

Search repository
Hidetoshi, Murakami

× Hidetoshi, Murakami

WEKO 996648

Hidetoshi, Murakami

Search repository
Kosuke, Shimizu

× Kosuke, Shimizu

WEKO 996649

Kosuke, Shimizu

Search repository
Sugie, Tatsuo

× Sugie, Tatsuo

WEKO 996650

Sugie, Tatsuo

Search repository
Takaki, Hatae

× Takaki, Hatae

WEKO 996651

Takaki, Hatae

Search repository
Tomohiko, Ushiki

× Tomohiko, Ushiki

WEKO 996652

en Tomohiko, Ushiki

Search repository
Ryota, Imazawa

× Ryota, Imazawa

WEKO 996653

en Ryota, Imazawa

Search repository
Hidetoshi, Murakami

× Hidetoshi, Murakami

WEKO 996654

en Hidetoshi, Murakami

Search repository
Kosuke, Shimizu

× Kosuke, Shimizu

WEKO 996655

en Kosuke, Shimizu

Search repository
Tatsuo, Sugie

× Tatsuo, Sugie

WEKO 996656

en Tatsuo, Sugie

Search repository
Takaki, Hatae

× Takaki, Hatae

WEKO 996657

en Takaki, Hatae

Search repository
抄録
内容記述タイプ Abstract
内容記述 This study developed a new correction method to reduce errors in temperature measurement caused by temperature-dependent emissivity for ITER divertor infrared (IR) thermography. In order to develop the method, we measured the spectral emissivity of tungsten from 200 °C to 1900 °C in the wavelength range of 1.5 μm to 4.5 μm and evaluated temperature measurement error of the two-color method. The results indicate that temperature-dependent emissivity is a major factor in temperature measurement errors, which suggests that accurately measuring temperature by using the conventional two-color method would prove difficult. The new correction method uses two emissivity inputs at different temperature points, in contrast to the conventional method, which uses emissivity measured at a single temperature point. Using this new correction method with a suitable wavelength combination for the two-color method, temperature measurement error was reduced to less than 5% at 1900 °C.
書誌情報 Fusion Engineering and Design

巻 168, p. 112665, 発行日 2021-05
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0920-3796
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2021.112665
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.fusengdes.2021.112665
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:35:41.405900
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3