WEKO3
アイテム
Longitudinal stability of a multimodal visco-elastic polyacrylamide gel phantom for magnetic resonance and ultrasound shear-wave elastography.
https://repo.qst.go.jp/records/82908
https://repo.qst.go.jp/records/82908453717b3-1cbd-4c3d-a85a-106a7f7add07
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-06-02 | |||||
タイトル | ||||||
タイトル | Longitudinal stability of a multimodal visco-elastic polyacrylamide gel phantom for magnetic resonance and ultrasound shear-wave elastography. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Usumura, Masashi
× Usumura, Masashi× Kishimoto, Riwa× Ishii, Koki× Hotta, Eika× Kershaw, Jeff× Higashi, Tatsuya× Obata, Takayuki× Suga, Mikio× Masashi, Usumura× Riwa, Kishimoto× Kershaw, Jeffrey× Tatsuya, Higashi× Takayuki, Obata |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We evaluated the long-term stability of a newly developed viscoelastic phantom made of polyacrylamide (PAAm) gel for magnetic resonance elastography (MRE) and ultrasound-based shear-wave elastography (US SWE). The stiffness of the cylindrical phantom was measured at 0, 13 and 18 months. Storage and loss moduli were measured with MRE, and shear-wave speed (SWS) was measured with US SWE. Long-term stability was evaluated in accordance with the Quantitative Imaging Biomarker Alliance (QIBA) profiles for each modality. The initial storage and loss moduli of the phantom were 5.01±0.22 and 1.11±0.15 respectively, and SWS was 2.57±0.04 m/s. The weight of the phantom decreased by 0.6% over the 18 months. When measured with MRE, the stiffness of the phantom decreased and changes to the storage and loss moduli were -3.0% and -4.6% between 0 and 13 months, and -4.3% and 0.0% between 0 and 18 months. The US measurements found that SWS decreased by 2.4% over the first 13 months and 3.6% at 18 months. These changes were smaller than the tolerances specified in the QIBA profiles, so the viscoelastic PAAm gel phantom fulfilled the condition for long-term stability. This new phantom has the potential to be used as a quality assurance and quality control phantom for MRE and US SWE. | |||||
書誌情報 |
PloS one 巻 16, 号 5, p. e0250667, 発行日 2021-05 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1932-6203 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 34019551 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1371/journal.pone.0250667 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0250667 |