WEKO3
-
RootNode
アイテム
Longitudinal stability of a multimodal visco-elastic polyacrylamide gel phantom for magnetic resonance and ultrasound shear-wave elastography.
https://repo.qst.go.jp/records/82908
https://repo.qst.go.jp/records/82908453717b3-1cbd-4c3d-a85a-106a7f7add07
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-06-02 | |||||
タイトル | ||||||
タイトル | Longitudinal stability of a multimodal visco-elastic polyacrylamide gel phantom for magnetic resonance and ultrasound shear-wave elastography. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Usumura, Masashi
× Usumura, Masashi× Kishimoto, Riwa× Ishii, Koki× Hotta, Eika× Kershaw, Jeff× Higashi, Tatsuya× Obata, Takayuki× Suga, Mikio× Masashi, Usumura× Riwa, Kishimoto× Kershaw, Jeffrey× Tatsuya, Higashi× Takayuki, Obata |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We evaluated the long-term stability of a newly developed viscoelastic phantom made of polyacrylamide (PAAm) gel for magnetic resonance elastography (MRE) and ultrasound-based shear-wave elastography (US SWE). The stiffness of the cylindrical phantom was measured at 0, 13 and 18 months. Storage and loss moduli were measured with MRE, and shear-wave speed (SWS) was measured with US SWE. Long-term stability was evaluated in accordance with the Quantitative Imaging Biomarker Alliance (QIBA) profiles for each modality. The initial storage and loss moduli of the phantom were 5.01±0.22 and 1.11±0.15 respectively, and SWS was 2.57±0.04 m/s. The weight of the phantom decreased by 0.6% over the 18 months. When measured with MRE, the stiffness of the phantom decreased and changes to the storage and loss moduli were -3.0% and -4.6% between 0 and 13 months, and -4.3% and 0.0% between 0 and 18 months. The US measurements found that SWS decreased by 2.4% over the first 13 months and 3.6% at 18 months. These changes were smaller than the tolerances specified in the QIBA profiles, so the viscoelastic PAAm gel phantom fulfilled the condition for long-term stability. This new phantom has the potential to be used as a quality assurance and quality control phantom for MRE and US SWE. | |||||
書誌情報 |
PloS one 巻 16, 号 5, p. e0250667, 発行日 2021-05 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1932-6203 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 34019551 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1371/journal.pone.0250667 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0250667 |
Share
Cite as
Usumura, Masashi, Kishimoto, Riwa, Ishii, Koki, Hotta, Eika, Kershaw, Jeff, Higashi, Tatsuya, Obata, Takayuki, Suga, Mikio, Masashi, Usumura, Riwa, Kishimoto, Kershaw, Jeffrey, Tatsuya, Higashi, Takayuki, Obata, n.d., Longitudinal stability of a multimodal visco-elastic polyacrylamide gel phantom for magnetic resonance and ultrasound shear-wave elastography.: e0250667– p.
Loading...