WEKO3
アイテム
A staggered 3-layer DOI PET detector using BaSO4 reflector for enhanced crystal identification and inter-crystal scattering event discrimination capability
https://repo.qst.go.jp/records/82881
https://repo.qst.go.jp/records/8288144e7e334-9038-4eb4-8253-9ad4cb7fb2d4
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-05-27 | |||||
タイトル | ||||||
タイトル | A staggered 3-layer DOI PET detector using BaSO4 reflector for enhanced crystal identification and inter-crystal scattering event discrimination capability | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kang, Hangyu
× Kang, Hangyu× Fumihiko, Nishikido× Taiga, Yamaya× Kang, Hangyu× Fumihiko, Nishikido× Taiga, Yamaya |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The spatial resolution of small animal positron emission tomography (PET)scanners can be improved by the use of crystals with fine pitch and rejection of inter-crystal scattering (ICS) events, which leads to a better quantification of radiopharmaceuticals. On the other hand, depth-of-interaction (DOI) information is essential to preserve the spatial resolution at the PET field-of-view(FOV) periphery while keeping the sensitivity. In this study we proposed a novel staggered 3-layer DOI detector using BaSO4 reflector material for an enhanced crystal identification performance as well as ICS event rejection capability over those of ESR reflector based DOI detectors. The proposed staggered 3-layer DOI detector had 3-layer staggered LYSO crystal arrays(crystal pitch = 1 mm), an acrylic light guide, and a 4 × 4 SiPM array. The 16 SiPM anode signals were read out by using a resistive network to encode the crystal position and energy information while the timing signal was extracted from the common cathode. The crystal map quality was substantially enhanced by using the BaSO4 reflector material as compared to that of the ESR reflector due to the low optical crosstalk between the LYSO crystals. The ICS events can be rejected with BaSO4 by using simple pulse height discrimination thanks to the light collection efficiency difference that depends on the crystal layers. As a result, the total number of events was decreased around 26% with BaSO4 as compared to that of ESR. The overall energy resolution and coincidence timing resolution with BaSO4were 19.7 ± 5.6% and 591 ± 160 ps, respectively which were significantly worse than 10.9 ± 2.2% and 308 ± 23 ps values of ESR because of the relatively low light collection efficiency with BaSO4 (1057 ± 308 ADC) compared to that of ESR (1808 ± 118 ADC). In conclusion, we found the proposed staggered 3-layer DOI detector using the BaSO4 reflector material with ICS event rejection capability can be a costeffective solution for realizing high resolution and highly sensitive small animal PET scanners while minimizing the complexity of the SiPM readout circuit. |
|||||
書誌情報 |
Biomedical Physics & Engineering Express 巻 7, 号 3, p. 035018, 発行日 2021-04 |
|||||
出版者 | ||||||
出版者 | IOP publishing | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2057-1976 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1088/2057-1976/abf6a8 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1088/2057-1976/abf6a8 |