WEKO3
アイテム
Precise measurement of uranium isotope ratios in Fukushima soils using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS)
https://repo.qst.go.jp/records/82861
https://repo.qst.go.jp/records/828614b5fdb0e-ca12-4de4-ab79-cc9e6db47924
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-05-24 | |||||
タイトル | ||||||
タイトル | Precise measurement of uranium isotope ratios in Fukushima soils using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Murugan, Rajamanickam
× Murugan, Rajamanickam× Veerasamy, Nimelan× Zhao, Ye× Aono, Tatsuo× Kumar Sahoo, Sarata× Murugan, Rajamanickam× Nimelan, Veerasamy× Tatsuo, Aono× Sahoo, Sarata |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Precise measurement of 234U/238U and 235U/238U isotope ratios was performed using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) in this study. The 234U ions were measured using a Daly detector, the 235U ions were measured using a Faraday cup with a 1012 U resistor, and the 238U ions were measured using a Faraday cup with the usual 1011 U resistor. Chemical separation of uranium was carried out by three different methods using either combinations of anion exchange and UTEVA resins or UTEVA resin three times. Chromatography combining three UTEVA resin columns provided the highest recovery (%) of uranium and biggest improvement in precise measurements of uranium isotope ratios. The certificate reference material (CRM) JLk-1 was used as an in-house standard for the uranium isotope ratio measurements. The long-term reproducibility of the in-house standard was 0.60% for 234U/238U and 0.05% for 235U/238U. The measured ratios were compared with the natural ratios, and the relative deviation obtained for uranium isotope ratios was less than 0.005% for 234U/238U and 235U/238U. Finally, the present method was applied to measure uranium isotope ratios in Fukushima microwave-digested soil samples. |
|||||
書誌情報 |
International Journal of Mass Spectrometry 巻 467, p. 116623, 発行日 2021-09 |
|||||
出版者 | ||||||
出版者 | ELSEVIER | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1387-3806 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.ijms.2021.116623 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.sciencedirect.com/science/article/abs/pii/S1387380621001032 |