ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

First imaging demonstration of a crosshair light-sharing PET detector

https://repo.qst.go.jp/records/82822
https://repo.qst.go.jp/records/82822
c7b2faa9-851c-4073-9247-2247259897e8
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-03-09
タイトル
タイトル First imaging demonstration of a crosshair light-sharing PET detector
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Eiji, Yoshida

× Eiji, Yoshida

WEKO 1007549

Eiji, Yoshida

Search repository
Go, Akamatsu

× Go, Akamatsu

WEKO 1007550

Go, Akamatsu

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 1007551

Hideaki, Tashima

Search repository
Kamada, Kei

× Kamada, Kei

WEKO 1007552

Kamada, Kei

Search repository
Yoshikawa, Akira

× Yoshikawa, Akira

WEKO 1007553

Yoshikawa, Akira

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1007554

Taiga, Yamaya

Search repository
Eiji, Yoshida

× Eiji, Yoshida

WEKO 1007555

en Eiji, Yoshida

Search repository
Go, Akamatsu

× Go, Akamatsu

WEKO 1007556

en Go, Akamatsu

Search repository
Hideaki, Tashima

× Hideaki, Tashima

WEKO 1007557

en Hideaki, Tashima

Search repository
Taiga, Yamaya

× Taiga, Yamaya

WEKO 1007558

en Taiga, Yamaya

Search repository
抄録
内容記述タイプ Abstract
内容記述 The crosshair light-sharing (CLS) PET detector is our original depth-of-interaction (DOI) detector, which is based on a single-ended readout scheme with quadrisected crystals comparable in size to a photo-sensor. In this work, we developed 32 CLS PET detectors, each of which consisted of a multipixel photon counter(MPPC) array and gadolinium fine aluminum garnet (GFAG) crystals, and we developed a benchtop prototype of a small animal size PET. Each GFAG crystal was 1.45 × 1.45 × 15 mm3. The MPPC had a surface area of 3.0 × 3.0 mm2. The benchtop prototype had two detector rings of 16 detector blocks. The ring diameter and axial field-of-view were 14.2 cm and 4.9 cm, respectively. The data acquisition system used was the PETsys silicon photomultiplier readout system. The continuous DOI information was binned into three DOI layers by applying a look-up-table to a 2D position histogram. Also, energy and timing information was corrected using DOI information. After the calibration procedure, the energy resolution and the coincidence time resolution were 14.6% and 531 ps, respectively. Imaging test results of a small rod phantom obtained by an iterative reconstruction method showed clear separation of 1.6 mm rods with the help of DOI information.
書誌情報 Physics in Medicine & Biology

巻 66, 号 6, p. 065013, 発行日 2021-03
出版者
出版者 IOP Science
ISSN
収録物識別子タイプ ISSN
収録物識別子 0031-9155
DOI
識別子タイプ DOI
関連識別子 10.1088/1361-6560/abe839
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1088/1361-6560/abe839
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:24:33.345378
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3