WEKO3
アイテム
Experience and performance of In Vivo Monitoring Laboratory of NIRP in 2017 thyroid measurement intercomparison
https://repo.qst.go.jp/records/82548
https://repo.qst.go.jp/records/82548044edc87-367e-40b8-ad7b-21ebdf426773
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-03-30 | |||||
タイトル | ||||||
タイトル | Experience and performance of In Vivo Monitoring Laboratory of NIRP in 2017 thyroid measurement intercomparison | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Osamu, Kurihara
× Osamu, Kurihara× Peng, Xuan× Zhang, Jianfeng× Wi-ho, Ha× Yang, Baolu× Osamu, Kurihara |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Determination of the 131I activity in the thyroid of exposed people or workers is one of the major concerns that needs to be addressed following a nuclear or radiological emergency. International intercomparison exercises on bioassay measurements are one of the effective methods to improve the capability and quality of internal dose assessment. In 2017, Working Group 1 (Internal Determination of the 131I activity in the thyroid of exposed people or workers is one of the major concerns that needs to be addressed following a nuclear or radiological emergency. International intercomparison exercises on bioassay measurements are one of the effective methods to improve the capability and quality of internal dose assessment. In 2017, Working Group 1 (Internal Dosimetry) of the Asian Radiation Dosimetry Group (ARADOS) organized an intercomparison exercise on the thyroid measurement, aiming at enhancing and coordinating the radiation dosimetry capabilities of Asian countries. This paper describes the measurement experience and results of In Vivo Monitoring Laboratory of NIRP in the 2017 intercomparison exercise, which can provide technical reference for laboratories that have not yet participated in such thyroid measurement intercomparsion. It covers technical aspects such as calibration, measurement and data processing. The results presented in this intercomparison are within an acceptable range of performance criteria on the bioassay measurements. In addition, further research work considered in the field of thyroid measurement is described in the discussion section | |||||
書誌情報 |
Applied Radiation and Isotopes 巻 168, p. 109492, 発行日 2021-02 |
|||||
出版者 | ||||||
出版者 | ELSEVIER | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0969-8043 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.apradiso.2020.109492 | |||||
関連サイト | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1016/j.apradiso.2020.109492 |