WEKO3
アイテム
Gamma-ray irradiation effects on optical coatings and polarizers for edge Thomson scattering system in ITER
https://repo.qst.go.jp/records/82391
https://repo.qst.go.jp/records/823911f2f6ef1-8597-4a4e-88b1-a84e59ae9d58
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2021-03-22 | |||||
| タイトル | ||||||
| タイトル | Gamma-ray irradiation effects on optical coatings and polarizers for edge Thomson scattering system in ITER | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Eiichi, Yatsuka
× Eiichi, Yatsuka× Torimoto, Kazuhiro× Masao, Ishikawa× Takaki, Hatae× Eiichi, Yatsuka× Torimoto, Kazuhiro× Masao, Ishikawa× Takaki, Hatae |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | This paper reports the gamma-ray irradiation effects on optical coatings and polarizers to be used in the ITERedge Thomson scattering system (ETS). Outside a diagnostic port-plug, in the Interspace, a total dose of the orderof 1 MGy is expected through 20 years of ITER operation. In this study, gamma-ray irradiation experiments wereperformed up to 10 MGy. A high peak power laser beam, i.e. a pulse energy of 5 J and a pulse duration of∼4 ns,is needed for a Thomson scattering measurement in ITER. Laser-induced damage threshold (LIDT) of anti-re-flection (AR) and high-reflection (HR) coatings at the laser wavelengths after gamma-ray irradiation were in-vestigated. LIDT of AR coating for 0° injections was more likely higher for the irradiated samples at a wavelengthof 1064 nm. Regarding HR coatings, LIDT was not noticeably degraded by gamma-ray irradiation. Regardingpolarizers, no degradation of transmission and extinction ratio was observed at visible and near infrared wa-velength ranges when a wire-grid polarizer substrate is made of fused silica. Since a signal of ETS is almostlinearly polarized, a wire-grid polarizer enables to improve signal to noise ratio of electron temperature anddensity measurements by Thomson scattering in ITER. | |||||
| 書誌情報 |
fusion engineering and design 巻 160, p. 111846, 発行日 2020-06 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0920-3796 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1016/j.fusengdes.2020.111846 | |||||
| 関連サイト | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | https://www.sciencedirect.com/science/article/pii/S092037962030394X | |||||