Influence of Lithium Mass Transfer on Tritium Behavior in Pebbles of Li2TiO3 with Excess Lithium

https://repo.qst.go.jp/records/82092
https://repo.qst.go.jp/records/82092
83aebe6f-b485-4d0f-9bca-696f9c7bfce1
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-03-09
タイトル
タイトル Influence of Lithium Mass Transfer on Tritium Behavior in Pebbles of Li2TiO3 with Excess Lithium
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Katayama, Kazunari

× Katayama, Kazunari

WEKO 1015593

Katayama, Kazunari

Search repository
Akito, Ipponsugi

× Akito, Ipponsugi

WEKO 1015594

Akito, Ipponsugi

Search repository
Hoshino, Tsuyoshi

× Hoshino, Tsuyoshi

WEKO 1015595

Hoshino, Tsuyoshi

Search repository
Katayama, Kazunari

× Katayama, Kazunari

WEKO 1015596

en Katayama, Kazunari

Search repository
Akito, Ipponsugi

× Akito, Ipponsugi

WEKO 1015597

en Akito, Ipponsugi

Search repository
Tsuyoshi, Hoshino

× Tsuyoshi, Hoshino

WEKO 1015598

en Tsuyoshi, Hoshino

Search repository
抄録
内容記述タイプ Abstract
内容記述 Tritium breeding ceramic materials are placed at high temperatures for a long period in a fusion DEMO reactor. Therefore, the understanding of Li mass loss phenomena and its influence on tritium behavior are important. In this study, the pebbles of Li2TiO3 with excess Li were heated at 900 °C for 30 days in a 1000 Pa H2/Ar flow and tritium sorption and recovery experiments were carried out. Li mass loss by the heating was evaluated to be 0.7 wt%. The value of Li mass loss was almost same as that for 3 days heating at the same condition. Tritium sorption capacity for the heated pebbles at 600 °C and 900 °C were almost same as that for the pebbles as received. Tritium sorbed in the pebbles could not be recovered effectively by the 1000 Pa H2/Ar purge at room temperature and 300 °C but it could be recovered at 600 °C and 900 °C. The influence of the long-time heating on the behavior of tritium sorbed in the pebbles was not large.
書誌情報 Fusion Engineering and Design

巻 161, p. 112011, 発行日 2020-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 0920-3796
DOI
識別子タイプ DOI
関連識別子 10.1016/j.fusengdes.2020.112011
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S0920379620305597
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:15:43.016122
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3