  1. 原著論文

Novel Cleaning Methodologies for Specimens Tested in Liquid Metals

https://repo.qst.go.jp/records/81937
https://repo.qst.go.jp/records/81937
23c9a90f-e1c3-409f-bc32-8370059bbcba
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-02-22
タイトル
タイトル Novel Cleaning Methodologies for Specimens Tested in Liquid Metals
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hatakeyama, Susumu

× Hatakeyama, Susumu

WEKO 1012932

Hatakeyama, Susumu

Search repository
Oono, Naoko

× Oono, Naoko

WEKO 1012933

Oono, Naoko

Search repository
Nozawa, Takashi

× Nozawa, Takashi

WEKO 1012934

Nozawa, Takashi

Search repository
Sakamoto, Kan

× Sakamoto, Kan

WEKO 1012935

Sakamoto, Kan

Search repository
Tamai, Yoshie

× Tamai, Yoshie

WEKO 1012936

Tamai, Yoshie

Search repository
Kondo, Masatoshi

× Kondo, Masatoshi

WEKO 1012937

Kondo, Masatoshi

Search repository
Takashi, Nozawa

× Takashi, Nozawa

WEKO 1012938

en Takashi, Nozawa

Search repository
抄録
内容記述タイプ Abstract
内容記述 Liquid metals are excellent coolants of fission and fusion reactors. However, the chemical compatibility of structural materials is important issue. The mass losses of the high-temperature materials such as FeCrAl-ODS, SiC, and refractory metals by corrosion in liquid metals are essential information to obtain their corrosion rates. The specimens must be cleaned to remove liquid metals solidified and adhered on the specimens after the corrosion tests, though the damage of the specimens in the cleaning procedure must be minimized. Cleaning methodologies appropriate for the specimens tested in liquid metals are urgently required for further compatibility study. The cleaning methodology with 0.1M sodium hydroxide (NaOH) solution was developed, in which Sn
was selectively dissolved without any damage on the specimens of the high-temperature materials. The cleaning procedure to remove Pb, Bi, and these alloys (i.e., Pb-16Li and Pb-Bi) adhered on the specimens in the solution mixture of acetic acid, ethanol, and H2O2 were also studied.
書誌情報 Plasma and Fusion Research

巻 16, p. 1205015, 発行日 2021-02
出版者
出版者 The Japan Society of Plasma Science and Nuclear Fusion Research
ISSN
収録物識別子タイプ ISSN
収録物識別子 1880-6821
DOI
識別子タイプ DOI
関連識別子 10.1585/pfr.16.1205015
関連サイト
識別子タイプ URI
関連識別子 http://www.jspf.or.jp/PFR/PFR_articles/pfr2021/pfr2021_16-1205015.html#ref
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:18:44.219261
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3