ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Gradiometer Using Separated Diamond Quantum Magnetometers

https://repo.qst.go.jp/records/81921
https://repo.qst.go.jp/records/81921
dd06f3f3-2315-47eb-871e-503427710095
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-02-04
タイトル
タイトル Gradiometer Using Separated Diamond Quantum Magnetometers
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yuta, Masuyama

× Yuta, Masuyama

WEKO 1012372

Yuta, Masuyama

Search repository
Suzuki, Katsumi

× Suzuki, Katsumi

WEKO 1012373

Suzuki, Katsumi

Search repository
Hekizono, Akira

× Hekizono, Akira

WEKO 1012374

Hekizono, Akira

Search repository
Iwanami, Mitsuyasu

× Iwanami, Mitsuyasu

WEKO 1012375

Iwanami, Mitsuyasu

Search repository
Mutsuko, Hatano

× Mutsuko, Hatano

WEKO 1012376

Mutsuko, Hatano

Search repository
Iwasaki, Takayuki

× Iwasaki, Takayuki

WEKO 1012377

Iwasaki, Takayuki

Search repository
Takeshi, Ohshima

× Takeshi, Ohshima

WEKO 1012378

Takeshi, Ohshima

Search repository
Yuta, Masuyama

× Yuta, Masuyama

WEKO 1012379

en Yuta, Masuyama

Search repository
Mutsuko, Hatano

× Mutsuko, Hatano

WEKO 1012380

en Mutsuko, Hatano

Search repository
Takeshi, Ohshima

× Takeshi, Ohshima

WEKO 1012381

en Takeshi, Ohshima

Search repository
抄録
内容記述タイプ Abstract
内容記述 The negatively charged nitrogen-vacancy (NV) center in diamonds is known as the spin defect and using its electron spin, magnetometry can be realized even at room temperature with extremely high sensitivity as well as a high dynamic range. However, a magnetically shielded enclosure is usually required to sense weak magnetic fields because environmental magnetic field noises can disturb high sensitivity measurements. Here, we fabricated a gradiometer with variable
sensor length that works at room temperature using a pair of diamond samples containing negatively charged NV centers. Each diamond is attached to an optical fiber to enable free sensor placement. Without any magnetically shielding, our gradiometer realizes a magnetic noise spectrum comparable
to that of a three-layer magnetically shielded enclosure, reducing the noises at the low-frequency range below 1 Hz as well as at the frequency of 50 Hz (power line frequency) and its harmonics. These results indicate the potential of highly sensitive magnetic sensing by the gradiometer using the NV center for applications in noisy environments such as outdoor and in vehicles.
書誌情報 Sensors

巻 21, 号 3, p. 977, 発行日 2021-02
出版者
出版者 MDPI
ISSN
収録物識別子タイプ ISSN
収録物識別子 1424-8220
DOI
識別子タイプ DOI
関連識別子 10.3390/s21030977
関連サイト
識別子タイプ URI
関連識別子 https://www.mdpi.com/1424-8220/21/3/977
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:19:17.526502
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3