Performance of first mirrors for divertor impurity monitor in ITER: compensation of misalignment and effect of beam divergence

https://repo.qst.go.jp/records/81854
https://repo.qst.go.jp/records/81854
f9186a2e-cd9b-4d03-9c4c-51d6d2bac036
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-02-17
タイトル
タイトル Performance of first mirrors for divertor impurity monitor in ITER: compensation of misalignment and effect of beam divergence
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kajita, S.

× Kajita, S.

WEKO 1012441

Kajita, S.

Search repository
Hiroaki, Ogawa

× Hiroaki, Ogawa

WEKO 1012442

Hiroaki, Ogawa

Search repository
Kitazawa, Sin-iti

× Kitazawa, Sin-iti

WEKO 1012443

Kitazawa, Sin-iti

Search repository
Toshihiro, Oikawa

× Toshihiro, Oikawa

WEKO 1012444

Toshihiro, Oikawa

Search repository
Veshchev, E.

× Veshchev, E.

WEKO 1012445

Veshchev, E.

Search repository
Hiroaki, Ogawa

× Hiroaki, Ogawa

WEKO 1012446

en Hiroaki, Ogawa

Search repository
Kitazawa, Sin-iti

× Kitazawa, Sin-iti

WEKO 1012447

en Kitazawa, Sin-iti

Search repository
Toshihiro, Oikawa

× Toshihiro, Oikawa

WEKO 1012448

en Toshihiro, Oikawa

Search repository
抄録
内容記述タイプ Abstract
内容記述 We investigated feasibility of an alignment method using first mirrors of the divertor impurity monitor (DIM) in ITER based on ray tracing analysis. A misalignment could occur between the divertor cassette and measurement system. It is shown that the misalignment can be compensated to some extent by rotating the first mirror. The maximum compensable misalignment and the required accuracy in the alignment are discussed. It is likely that the surface roughness of the first mirrors gradually increases during ITER operation. We investigated the required quality of the first mirror as focusing on the beam divergence using the ray tracing model. Moreover, to check the performance, helium plasma irradiation was performed on molybdenum mirror samples, and the beam divergence was measured using a laser and a detector. Based on the simulations and experiments, it is shown that the helium effect does not harm the performance of the mirror when the mirror temperature is less than 800 K.
書誌情報 Journal of Instrumentation

巻 15, p. P11035, 発行日 2020-11
出版者
出版者 IOP Publishing
ISSN
収録物識別子タイプ ISSN
収録物識別子 1748-0221
DOI
識別子タイプ DOI
関連識別子 10.1088/1748-0221/15/11/P11035
関連サイト
識別子タイプ URI
関連識別子 https://iopscience.iop.org/article/10.1088/1748-0221/15/11/P11035
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:19:12.175682
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3